SLLSFF7B May   2021  – August 2026 ISOW1044

PRODUCTION DATA  

  1.   1
  2. 1 Features
  3. 2 Applications
  4. 3 Description
  5. 4 Device Comparison Table
  6. 5 Pin Configuration and Functions
  7. 6 Specifications
    1. 6.1  Absolute Maximum Ratings
    2. 6.2  ESD Ratings
    3. 6.3  Recommended Operating Conditions
    4. 6.4  Thermal Information
    5. 6.5  Power Ratings
    6. 6.6  Insulation Specifications
    7. 6.7  Safety-Related Certifications
    8. 6.8  Safety Limiting Values
    9. 6.9  Electrical Characteristics
    10. 6.10 Supply Current Characteristics
    11. 6.11 Switching Characteristics
    12. 6.12 Insulation Characteristics Curves
    13. 6.13 Typical Characteristics
  8. 7 Parameter Measurement Information
  9. 8 Detailed Description
    1. 8.1 Overview
    2. 8.2 Power Isolation
    3. 8.3 Signal Isolation
    4. 8.4 CAN Transceiver
    5. 8.5 Remote Wake Request Using Wake-Up Pattern (WUP) in Standby Mode
    6. 8.6 Functional Block Diagram
    7. 8.7 Feature Description
      1. 8.7.1 CAN Bus States
      2. 8.7.2 Digital Inputs and Outputs: TXD (Input) and RXD (Output)
      3. 8.7.3 TXD Dominant Timeout (DTO)
      4. 8.7.4 Power-Up and Power-Down Behavior
      5. 8.7.5 Protection Features
      6. 8.7.6 Floating Pins, Unpowered Device
      7. 8.7.7 Glitch-Free Power Up and Power Down
    8. 8.8 Device Functional Modes
    9. 8.9 Device I/O Schematics
  10. 9 Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
        1. 9.2.2.1 Bus Loading, Length and Number of Nodes
        2. 9.2.2.2 CAN Termination
      3. 9.2.3 Application Curve
        1. 9.2.3.1 Insulation Lifetime
    3. 9.3 Power Supply Recommendations
    4. 9.4 Layout
      1. 9.4.1 Layout Guidelines
      2. 9.4.2 Layout Example
  11. 10Device and Documentation Support
    1. 10.1 Documentation Support
      1. 10.1.1 Related Documentation
    2. 10.2 Receiving Notification of Documentation Updates
    3. 10.3 Support Resources
    4. 10.4 Trademarks
    5. 10.5 Electrostatic Discharge Caution
    6. 10.6 Glossary
  12. 11Revision History
  13. 12Mechanical, Packaging, and Orderable Information

Features

  • Meets the requirements of ISO 11898-2:2016 physical layer standards
    • Support of Classical CAN: 1Mbps
    • Optimized for CAN FD: 2 and 5Mbps
  • Integrated DC-DC converter with low-emissions, low-noise
    • Meets CISPR 32 and EN 55032 Class B with greater than 6dB margin on a two-layer PCB
    • Low frequency power converter at 25MHz enabling low noise performance
  • Additional 10Mbps GPIO channel
  • High efficiency output power
    • Typical efficiency: 47%
    • Isolated output voltage accuracy: ± 5%
    • Additional output current: 20mA
  • Independent power supply for CAN and DC-DC
    • Logic supply (VIO): 1.71V to 5.5V
    • Power converter supply (VDD): 4.5V to 5.5V
  • Fault-Protected CAN FD Transceiver
    • DC Bus fault protection voltage: ± 58V
    • Receiver common mode input voltage: ±12V
    • Remote wakeup using BUS wake-up pattern
  • Typical loop delay: 167ns
  • Reinforced and Basic isolation options
  • High CMTI: 100kV/µs (typical)
  • High ESD bus protection with respect to GND2
    • HBM ESD: ±12kV
    • IEC 61000-4-2 contact discharge: ±8kV
  • Operating temperature range: -40°C to 125°C
  • Current limit and thermal shutdown
  • 20-pin wide SOIC package
  • Safety-Related Certifications:
    • VDE Reinforced and Basic insulation per DIN EN IEC 60747-17 (VDE 0884-17)
    • UL 1577 component recognition program
    • IEC 62368-1, IEC 61010-1, IEC 60601-1 and GB 4943.1 certifications