Total Harmonic Distortion (THD)

Total harmonic distortion is a single number that interprets output spectrum measurements from the previous chapter. Table 5-3, Figure 5-19 and Figure 5-20 document the results.

Table 5-3 Total Harmonic Distortion
Input type Value Unit
Harmonic signal THD 1.15 %
Modulated PWM signal THD 3.24 %
 Total Harmonic Distortion (Harmonic
                                                  Signal) Figure 5-19 Total Harmonic Distortion (Harmonic Signal)