Capacitor Influence on Sampling Time

The Y capacitance in insulation testing has a great influence on the speed of insulation testing. The mechanism of the Y capacitance affecting insulation detection is, for example, in the bridge method, that it delays the time of steady state establishment, if the unconverged voltage value is used to calculate, The resulting insulation resistance value is also inaccurate.

 Y Capacitor in Insulation
                    Circuit Figure 4-1 Y Capacitor in Insulation Circuit