SLUSFK8 April 2024 BQ25770G
PRODUCTION DATA
Converter can be configured under quasi dual phase buck boost operation through MODE pin referring to Table 7-1. The charger operates in buck, buck-boost and boost mode under different VBUS and VSYS combination. The buck-boost can operate seamlessly across the three operation modes. The 6 main switches operating status under continuous conduction mode (CCM) are listed below for reference.
| MODE | BUCK | BUCK-BOOST | BOOST |
|---|---|---|---|
| Q1_A | Switching at Fsw (interleave with Q1_B) | Switching (sequence with Q1_B and Q4) | ON |
| Q2_A | Switching at Fsw (interleave with Q2_B) | Switching (sequence with Q2_B and Q3) | OFF |
| Q1_B | Switching at Fsw (interleave with Q1_A) | Switching (sequence with Q1_A and Q4) | ON |
| Q2_B | Switching at Fsw (interleave with Q2_A) | Switching (sequence with Q2_A and Q3) | OFF |
| Q3 | OFF | Switching (sequence with Q2_A and Q2_B) | Switching at 2*Fsw |
| Q4 | ON | Switching (sequence with Q1_A and Q1_B) | Switching at 2*Fsw |