SLUSG21C May 2025 – August 2026 UCC25661
PRODUCTION DATA
To maximize efficiency, use a bias winding to use the HV start-up function. Design the bias winding so that the VCCP voltage is greater than 12V.
Built or purchase the transformer according to these specifications:
For some applications that operate at a wide input LLC where the PFC is potentially shut off in standby mode, the operating frequency can be lower during heavy load shutdown and the LLC operates at just above the ZCS boundary, which is a lower frequency. Rate the magnetic components in the resonant circuit, transformer inductor, and resonant inductor to operate at the lower frequency.
The bias voltage is obtained as 18V as per the turns ratio. To reduce the controller voltage to 15V, use a voltage regulator circuit like in the UCC25661EVM-128 before supplying to VCCP of the controller.