SLVSCV8E December 2015 – June 2025 TPS4H160-Q1
PRODUCTION DATA
Table 7-2 applies when the DIAG_EN pin is enabled.
| CONDITIONS | INx | OUTx | THER | CRITERION | STx (VER. A) | CS (VER. B) | FAULT (VER. B) | FAULT RECOVERY |
|---|---|---|---|---|---|---|---|---|
| Normal | L | L | — | — | H | 0 | H | — |
| H | H | — | — | H | In linear region | H | — | |
| Overlaod, short to ground | H | L | — | Current limit triggered | L | VCS(H) | L | Auto |
| Open load(1), short to battery, reverse polarity | L | H | — | VVS – VOUTx < V(ol,off) | L | VCS(H) | L | Auto |
| Thermal shutdown | H | — | L | TSD triggered | L | VCS(H) | L | Output auto-retry. Fault recovers when TJ < T(SD,rst) or when INx toggles. |
| H | Output latch off. Fault recovers when INx toggles. | |||||||
| Thermal swing | H | — | — | TSW triggered | L | VCS(H) | L | Auto |