SLVSH18B December 2024 – July 2025 TPS4HC120-Q1
PRODUCTION DATA
| PART NUMBER | BEHAVIOR AFTER THERMAL FAULT |
|---|---|
| TPS4HC120A-Q1 | LATCH off the faulted channel after thermal fault. Toggle EN to re-enable the specific channel. |
| TPS4HC120B-Q1 | Auto-retry after thermal fault. |