15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | Default |
0 | UVRVM | 0 | MODE | TER | 0 | OLOFF | 0 | 0 | 0 | 0 | ERR3 | ERR2 | ERR1 | ERR0 | 5800h | |
Field | Bits | Type | Description |
UVRVM | 14 | R | VM Undervoltage monitor
|
MODE | 12-11 | R | Mode of operation monitor
|
TER | 10 | R | Transmission error 0b: Previous transmission was successful (modulo 16 + n*8 clocks received, where n = 0, 1, 2...) 1b (default): Previous transmission failed. The first frame after a reset is TER set to 1b and the INST register. The second frame is the Standard Diagnosis with TER set to 0b (if there was no fail in the previous transmission). |
OLOFF | 8 | R | Open load in OFF diagnosis 0b (default): All channels in OFF state (which have IOLx bit set to 1b) have VDS > VDS_OL 1b: At least one channel in OFF state (with IOLx bit set to 1b) has VDS < VDS_OL. Channels in ON state are not considered. |
ERRx | 3-0 | R | Overload / Over temperature Diagnosis of Channel x 0b (default): No failure detected 1b: Over temperature or overload |