SLVSH58B November 2024 – January 2025 DRV81004-Q1
PRODUCTION DATA
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 | Default |
R = 0 W = 1 | R = 1 W = 0 | 0011 | 00 | ACT | RST | DISOL | OCP | RSVD | PAR1 | PAR0 | 00h | |||||
Field | Bits | Type | Description |
ACT | 7 | RW | 0b (default): Normal operation or device leaves Active Mode 1b: Device enters Active Mode |
RST | 6 | RW | 0b (default): Normal operation 1b: Execute Reset command (self clearing) |
DISOL | 5 | RW | 0b (default): Open load detection is enabled 1b: Open load detection is disabled |
OCP | 4 | RW | 0b (default): Overcurrent protection current profile 1 1b: Overcurrent protection current profile 2 |
RSVD | 3-2 | RW | Reserved. Read default: 0b , write ignored. |
PAR1 | 1 | RW | 0b (default): Normal operation 1b: Channel 1 and 3 have Over Load and Over Temperature synchronized |
PAR0 | 0 | RW | 0b (default): Normal operation 1b: Channel 0 and 2 have Over Load and Over Temperature synchronized |