The thermal protection behavior can be split up
into two categories of events that can occur.
Thermal Behavior for Auto-Retry Version
shows each of these categories.
- Relative thermal shutdown: the device is
enabled into an overcurrent event. The output
current rises up to the IILIM level and
the FLT goes low. With this
large amount of current going through the junction
temperature of the FET increases rapidly with
respect to the controller temperature. When the
power FET temperature rises TREL amount
above the controller junction temperature ΔT =
TFET – TCON >
TREL, the device shuts down. For
auto-retry version, after tRETRY, the
part tries to restart itself. Latch version
requires EN to be toggled to re-enable the
channel. The FLT is asserted
until the fault condition is cleared.
- Absolute thermal shutdown: The device is
still enabled in an overcurrent event. However, in this case the junction
temperature rises up and hits an absolute reference temperature,
TABS, and then shuts down. For auto-retry version, the device does
not recover until both TJ < TABS – Thys and
the tRETRY timer has expired. For latch version, toggling EN is
required to re-enable the channel.