SLVSL93A March 2026 – April 2026 UCC34141
PRODUCTION DATA
Depending on the input and output conditions, ENA pin voltage, as well as the device temperature, the UCC34141 operates in one of the below operation modes.
Table 7-1 lists the supply functional modes for this device. The ENA pin has an internal weak pull-down resistance to ground, but TI does not recommend leaving this pin open.
|
INPUT |
OUTPUTS |
OPERATION MODE | ||||
|---|---|---|---|---|---|---|
| VVIN | ENA | FAULT | V(VDD – COM) Isolated Output1 |
V(COM – VEE) Isolated Output2 |
Power-Good(1)
(2) Open Drain |
|
| VVIN < VVIN_UVLO_R | X | X | OFF | OFF | Non-Active Status | Protection mode, auto-recovery |
| VVIN_UVLO_R < VVIN < VVIN_OVLO_R | LOW | X | OFF | OFF | Non-Active Status | Disable mode |
| VVIN_UVLO_R < VVIN < VVIN_OVLO_R | HIGH | NO FAULT | Regulating at Setpoint | Regulating at Setpoint | Active Status | Normal operation |
| VVIN_UVLO_R < VVIN < VVIN_OVLO_R | HIGH | YES FAULT | OFF | OFF | Non-Active Status | Protection mode, latched-off or auto-restart after tRESTART |
| VVIN > VVIN_OVLO_R | X | X | OFF | OFF | Non-Active Status | Protection mode, auto-recovery |