Bode Plots

Bode plot is shown in Figure 2-3. Crossover frequency at 230VAC, 3A load is 1.861 kHz, phase margin 67.33 deg. and gain margin 11.75dB. The remaining two measurements are associated to 1A and 2A load.

PMP31375 Bode Plot of the Converter. Dashed
          Line Refers to 230VAC and 3A Load Figure 2-3 Bode Plot of the Converter. Dashed Line Refers to 230VAC and 3A Load