2.4.6 Probe the Serial Management Interface Signals (MDC, MDIO)
MDIO should pull up to the I/O supply when undriven. Probe MDIO to confirm the
default voltage.
Confirm processor and PHY have the same VDDIO voltage.
MDC should not have any pull up or pull down resistor.
Attempt to read the registers. Probe the MDC/MDIO signals during read and write
operations, referencing the expected waveforms in the following images.
Figure 2-4 Typical MDC/MDIO Read
Operation
Figure 2-5 Typical MDC/MDIO Write
Operation
Note: Recommend using Logic Analyzer to
debug MDIO communication.