SNOSDG7A May 2025 – March 2026 TPS7H6101-SEP
PRODUCTION DATA
Combining foster networks with additional systems thermal resistances or impedance networks increases the fidelity of the overall system model, which provides improved junction temperature modeling. Applying the network in Figure 9-8, then apply a current source to the input terminal (RC1) corresponding to the modeled power dissipation profile; then add external system thermal resistances / impedance (board attach solder, PCB, chassis connection etc.). Implementing this network in common electrical simulation platforms provides a fast and efficient method for determining overall system performance.
| Foster network parameters: | ||||||
| HS | LS | |||||
| RTHi (°C/W) | τi(s) | RTHi (°C/W) | τi(s) | |||
| 1 | 237m | 1μ | 450m | 1μ | ||
| 2 | 135m | 19μ | 271m | 19μ | ||
| 3 | 118m | 19μ | 223m | 19μ | ||
| 4 | 232m | 422μ | 437m | 438μ | ||
| 5 | 284m | 422μ | 594m | 445μ | ||
| 6 | 10m | 411μ | 10m | 411μ | ||
| 7 | 293m | 422μ | 620m | 447μ | ||
| 8 | 349m | 422μ | 814m | 456μ | ||
| 9 | 326m | 422μ | 732m | 452μ | ||
| 10 | 400m | 700μ | 400m | 700μ | ||