SNOSDG7A May 2025 – March 2026 TPS7H6101-SEP
PRODUCTION DATA
The transient thermal impedance curve of the TPS7H6101 is shown in Figure 9-7; including the Foster model, which shows a high degree of fitting to the high side (HS) and low side (LS) curves. Figure 9-8 illustrates the implemented Foster RC thermal model network with the parameters tabulated below Figure 9-8.