The LP5816 enters STANDBY mode when CHIP_EN = 0 or NORMAL mode when CHIP_EN =
1 after exiting from INITIALIZATION mode or THERMAL SHUTDOWN mode.
While staying in STANDBY or NORMAL
mode,
when Enter Shutdown Method is applied, the LP5816 enters SHUTDOWN mode. The Enter Shutdown Method is
described in Shutdown Mode.
when the junction temperature
of the LP5816 rises above the thermal shutdown
threshold TSD, the LP5816 turns off
all output channels and enters THERMAL SHUTDOWN mode.