SNVSCQ9 November 2025 LM68425-Q1
PRODUCTION DATA
In addition to power-good monitoring, the LM684x5-Q1 includes a redundant output voltage monitoring feature to help further reduce the residual FIT (failure in time) rate in safety relevant applications. This function monitors the output voltage through the VSNS pin. The redundant VOUT monitor open drain output (nFAULT) switches to a high impedance when the output voltage is in regulation. When the output voltage exceeds the 12.5% threshold above the set voltage, the device responds by asserting the nFAULT pin low within 0.5μs response time and the device stops switching. An enable (EN) pin toggle is required to clear the latch to restart the switching action.
The redundant output voltage monitor function is powered through the EN pin and uses a redundant internal voltage reference for complete output voltage monitoring redundancy. The function can be disabled by shorting the nFAULT pin to GND.