This section describes the currently known issues on each EVM revision and applicable workarounds. Issues that have been patched have modification labels attached to the EVM assembly.
| Issue Number | Issue Title | Issue Description | Variant Affected |
|---|---|---|---|
| 1 | HDMI, DSS Incorrect Colors | HDMI Transmitter on E1 boards shows incorrect colors. | E1 |
| 2 | J9 and J10 Header Allignment | MCU and PRU headers are missaligned on E1 | E1 |
| 3 | USB Boot Descoped on E1 | USB Boot is not available on E1 boards | E1 |
| 4 | OLDI Connector Orientation and Pinout | OLDI Connector Pinout changed and an adapter is required for E1/E2 boards. | E1, E2 |
| 5 | Bluetooth Descoped on E2 | Bluetooth does not work on E2 boards. | E1, E2 |
| 6 | Ethernet PHY CLK Skew default Strapping | Default PHY Tx CLK Skew needs to be set to 0ns | E1, E2 |
| 7 | TEST_POWERDOWN signals shorted | Resistor change required to avoid backflow from VMain | E1, E2 |
| 8 | SD Card Detect Signal | MMC1_SDCD line can cause spurious interrupts to the SoC under certain conditions. | E1, E2 |
| 9 | PD Controller I2C2 IRQ Not Pinned Out | I2C_IRQ signal from PD controller not pinned out resulting in problems with regard to USB Host and Device mode operation. | E1, E2 |
| 10 | INA Current Monitor Adress Changes | INA adress lines changed to adress spurious address changes. | E1, E2 |