TIDUFK0 October   2026

 

  1.   1
  2.   Description
  3.   Resources
  4.   Features
  5.   Applications
  6. 1System Description
    1. 1.1 Key System Specifications
  7. 2System Overview
    1. 2.1 Block Diagram
    2. 2.2 Design Considerations
      1. 2.2.1 Step-Down Converter Subsystem
      2. 2.2.2 Digital-to-Analog Control Set Path
      3. 2.2.3 High-Precision Measurement Front-End (Feedback Path)
    3. 2.3 Highlighted Products
      1. 2.3.1 TPSM8F7x20
      2. 2.3.2 ADS9308V8I
      3. 2.3.3 TMDSCNCD28P65X
      4. 2.3.4 DAC80504
      5. 2.3.5 REF50
      6. 2.3.6 OPAx990
  8. 3System Design Theory
    1. 3.1 Converter Step Down Range
    2. 3.2 Fault Clamping Protection
    3. 3.3 Current Clamping Behavior
  9. 4Hardware, Software, Testing Requirements, and Test Results
    1. 4.1 Hardware Requirements
    2. 4.2 Software
    3. 4.3 Test Setup
    4. 4.4 Test Results
      1. 4.4.1 Voltage Linearity test
      2. 4.4.2 Voltage Regulation Test
      3. 4.4.3 Current Linearity Test
      4. 4.4.4 Output Voltage Ripple
      5. 4.4.5 Full Load Transient Response
      6. 4.4.6 Sudden Load Switch In with Current Clamping Response
      7. 4.4.7 Full Load Voltage Settling Time
  10. 5Design and Documentation Support
    1. 5.1 Tools and Software
      1. 5.1.1 Tools
      2. 5.1.2 Software
    2. 5.2 Documentation Support
    3. 5.3 Support Resources
    4.     Trademarks
  11. 6About the Author

Hardware Requirements

This reference design can be setup using the following equipment:

  • 12V power supply with capability of 120W output
  • Oscilloscope with current probe and voltage probe
  • 6.5 digital multimeter for voltage and current calibration
  • Computer for real time system control and measurements
TIDA-011001 Hardware RequirementsFigure 4-1 Hardware Requirements