AFE4432

AKTIV

Extra kleines integriertes AFE mit niedrigem Stromverbrauch und hohem Rauschabstand für optische Wea

Produktdetails

Applications HRV, Hearables, Optical-HRM, Optical-HRM for wearables, SpO2, Vo2 max Number of input channels 3 Resolution (Bits) 22 Number of LEDs 4 Interface type I2C, SPI Operating temperature range (°C) -40 to 85 Rating Catalog
Applications HRV, Hearables, Optical-HRM, Optical-HRM for wearables, SpO2, Vo2 max Number of input channels 3 Resolution (Bits) 22 Number of LEDs 4 Interface type I2C, SPI Operating temperature range (°C) -40 to 85 Rating Catalog
DSBGA (YCH) 25 3.0625 mm² 1.75 x 1.75
  • Supports signal acquisition of up to 12 phase sets
  • Supports up to 4 LEDs, 3 PDs
  • Flexible allocation of LEDs, PDs in each phase
  • Simultaneous signal acquisition from different sensors at different data rates
  • Accurate, continuous PPG monitoring:
    • Low current for continuous heart-rate monitoring on a wearable device with a typical value: 12 µA for the receiver
    • Peak system SNR of 115 dB in 0.5-10 Hz band enables high-accuracy SpO2 measurement
  • Transmitter:
    • 8-Bit Programmable LED current with range adjustable from 25 mA to 250 mA
    • Mode to fire two LEDs in parallel with independent per-phase current control
    • Programmable LED on-time per-phase
    • Simultaneous support of 4 LEDs for SpO2, Multi-Wavelength HRM
  • Receiver:
    • Supports 3 Time-Multiplexed PD Inputs
    • 2 parallel receivers (2 sets of TIA/filter)
    • Individual ambient offset subtraction DAC at each TIA Input with 8-bit per-phase control and range adjustable up to 255-µA
    • Individual LED offset subtraction DAC at each TIA input with 9-bit per-phase control and 64-µA range
    • Digital ambient subtraction at ADC output
    • Noise filtering with programmable bandwidth
    • Transimpedance gain: 3.7 kΩ to 1 MΩ
  • Supports external clock or internal oscillator
  • Option to acquire data synchronized with a system clock
  • Automatic cancellation of DC from Ambient, LED
  • FIFO with 160-sample depth
  • SPI™ interface/ I2C interface
  • 1.9-mm × 1.8-mm DSBGA, 0.35-mm Pitch
  • Supplies: Rx:1.7 - 1.9 V, Tx: 3-5.5 V
  • Supports signal acquisition of up to 12 phase sets
  • Supports up to 4 LEDs, 3 PDs
  • Flexible allocation of LEDs, PDs in each phase
  • Simultaneous signal acquisition from different sensors at different data rates
  • Accurate, continuous PPG monitoring:
    • Low current for continuous heart-rate monitoring on a wearable device with a typical value: 12 µA for the receiver
    • Peak system SNR of 115 dB in 0.5-10 Hz band enables high-accuracy SpO2 measurement
  • Transmitter:
    • 8-Bit Programmable LED current with range adjustable from 25 mA to 250 mA
    • Mode to fire two LEDs in parallel with independent per-phase current control
    • Programmable LED on-time per-phase
    • Simultaneous support of 4 LEDs for SpO2, Multi-Wavelength HRM
  • Receiver:
    • Supports 3 Time-Multiplexed PD Inputs
    • 2 parallel receivers (2 sets of TIA/filter)
    • Individual ambient offset subtraction DAC at each TIA Input with 8-bit per-phase control and range adjustable up to 255-µA
    • Individual LED offset subtraction DAC at each TIA input with 9-bit per-phase control and 64-µA range
    • Digital ambient subtraction at ADC output
    • Noise filtering with programmable bandwidth
    • Transimpedance gain: 3.7 kΩ to 1 MΩ
  • Supports external clock or internal oscillator
  • Option to acquire data synchronized with a system clock
  • Automatic cancellation of DC from Ambient, LED
  • FIFO with 160-sample depth
  • SPI™ interface/ I2C interface
  • 1.9-mm × 1.8-mm DSBGA, 0.35-mm Pitch
  • Supplies: Rx:1.7 - 1.9 V, Tx: 3-5.5 V

The AFE4432 is an analog front-end for optical bio-sensing applications, such as heart-rate monitoring (HRM) and saturation of peripheral capillary oxygen (SpO2). The device supports up to 4 switching light-emitting diodes (LEDs) and up to three photodiodes (PDs). The AFE has two LED drivers each with 8-bit current control. The device has a high dynamic range transmit-and-receive circuitry that helps with the sensing of very small signal levels. Up to 12 signal phase sets can be defined, each phase set comprising a combination of LED and Ambient phases. Low noise offset DACs at the receiver inputs can be automatically controlled to cancel DC from Ambient and LED light. The current from the PDs in each phase is converted into voltage by TIAs, filtered, and then digitized using a common ADC. The ADC code can be stored in a 160-sample FIFO block. The FIFO can be read out using a SPI or I2C interface.

The AFE4432 is an analog front-end for optical bio-sensing applications, such as heart-rate monitoring (HRM) and saturation of peripheral capillary oxygen (SpO2). The device supports up to 4 switching light-emitting diodes (LEDs) and up to three photodiodes (PDs). The AFE has two LED drivers each with 8-bit current control. The device has a high dynamic range transmit-and-receive circuitry that helps with the sensing of very small signal levels. Up to 12 signal phase sets can be defined, each phase set comprising a combination of LED and Ambient phases. Low noise offset DACs at the receiver inputs can be automatically controlled to cancel DC from Ambient and LED light. The current from the PDs in each phase is converted into voltage by TIAs, filtered, and then digitized using a common ADC. The ADC code can be stored in a 160-sample FIFO block. The FIFO can be read out using a SPI or I2C interface.

Herunterladen Video mit Transkript ansehen Video
Weitere Informationen anfordern

Das vollständige Datenblatt und weitere Designressourcen sind unter NDA verfügbar. Jetzt anfordern

Ähnliche Produkte, die für Sie interessant sein könnten

Selbe Funktionalität wie der verglichene Baustein bei abweichender Anschlussbelegung
AFE4460 AKTIV Integriertes AFE, hoher SNR, extrem niedriger Stromverbrauch für optische Wearable-Biosensorik – mit Same functionality with >116-dB dynamic range, 32 LEDs, automatic ambient cancellation, 1.8-V operation
AFE44I30 AKTIV Ultra-Low-Power integriertes Analog-Frontend (AFE) für optische Wearable-Biosensorik mit FIFO und I² Same functionality with 108-dB dynamic range, I2C interface, automatic ambient cancellation, 1.8-V operation
AFE44S30 AKTIV Ultra-Low-Power integriertes Analog-Frontend (AFE) für optische Wearable-Biosensorik mit FIFO und SP Same functionality with 108-dB dynamic range, SPI, automatic ambient cancellation, 1.8-V operation

Technische Dokumentation

star =Von TI ausgewählte Top-Empfehlungen für dieses Produkt
Keine Ergebnisse gefunden. Bitte geben Sie einen anderen Begriff ein und versuchen Sie es erneut.
Alle anzeigen 4
Typ Titel Datum
* Data sheet AFE4432 Ultra-Small, Integrated AFE for Optical Bio-Sensing datasheet PDF | HTML 23 Aug 2022
Product overview Photoplethysmography (PPG) With Integrated AFE for Optical Biosensing PDF | HTML 30 Okt 2023
Application brief Measuring Oxygen Saturation (SpO2) on Wearables PDF | HTML 14 Nov 2022
Application brief Optical Heart Rate Monitoring (OHRM) on Wearables PDF | HTML 14 Nov 2022

Design und Entwicklung

Weitere Bedingungen oder erforderliche Ressourcen enthält gegebenenfalls die Detailseite, die Sie durch Klicken auf einen der unten stehenden Titel erreichen.

Evaluierungsplatine

AFE4432EVM — AFE4432 Evaluierungsmodul für extrem kleines, integriertes AFE mit extrem geringem Stromverbrauch un

Das Evaluierungsmodul (EVM) AFE4432 ist eine Plattform zur Evaluierung des AFE4432, eines analogen Frontends (AFE), für optische Biosensoranwendungen wie Geräte zur Bestimmung der Pulsfrequenz (HRM) und der Sauerstoffsättigung des kapillaren Blutes (SpO2). AFE4432 unterstützt bis zu vier schaltende (...)

Treiber oder Bibliothek

AFE4432-DESIGN AFE4432 design files for high-performance smallest-size PPG AFE for hearables and wearables

The full data sheet and other design resources for this device are available here.
Unterstützte Produkte und Hardware

Unterstützte Produkte und Hardware

Produkte
Biosensorik-AFEs
AFE4432 Extra kleines integriertes AFE mit niedrigem Stromverbrauch und hohem Rauschabstand für optische Wea
Hardware-Entwicklung
Evaluierungsplatine
AFE4432EVM AFE4432 Evaluierungsmodul für extrem kleines, integriertes AFE mit extrem geringem Stromverbrauch un
Simulationstool

PSPICE-FOR-TI — PSpice® für TI Design-und Simulationstool

PSpice® für TI ist eine Design- und Simulationsumgebung, welche Sie dabei unterstützt, die Funktionalität analoger Schaltungen zu evaluieren. Diese voll ausgestattete Design- und Simulationssuite verwendet eine analoge Analyse-Engine von Cadence®. PSpice für TI ist kostenlos erhältlich und (...)
Gehäuse Pins CAD-Symbole, Footprints und 3D-Modelle
DSBGA (YCH) 25 Ultra Librarian

Bestellen & Qualität

Beinhaltete Information:
  • RoHS
  • REACH
  • Bausteinkennzeichnung
  • Blei-Finish/Ball-Material
  • MSL-Rating / Spitzenrückfluss
  • MTBF-/FIT-Schätzungen
  • Materialinhalt
  • Qualifikationszusammenfassung
  • Kontinuierliches Zuverlässigkeitsmonitoring
Beinhaltete Information:
  • Werksstandort
  • Montagestandort

Empfohlene Produkte können Parameter, Evaluierungsmodule oder Referenzdesigns zu diesem TI-Produkt beinhalten.

Support und Schulungen

TI E2E™-Foren mit technischem Support von TI-Ingenieuren

Inhalte werden ohne Gewähr von TI und der Community bereitgestellt. Sie stellen keine Spezifikationen von TI dar. Siehe Nutzungsbedingungen.

Bei Fragen zu den Themen Qualität, Gehäuse oder Bestellung von TI-Produkten siehe TI-Support. ​​​​​​​​​​​​​​

Videos