LMP91200
Integriertes AFE für energieeffiziente pH-Sensoranwendungen
LMP91200
- Active Guarding
- Key Specifications
Unless otherwise noted, typical values at
TA = 25°C, VS = (VDD-GND) = 3.3 V - pH Buffer Input Bias Current (0 < VINP < 3.3 V)
- Maximum at 25°C: ±125 fA
- Maximum at 85°C: ±445 fA
- pH Buffer Input Bias Current
(–500 mV < VINP– VCM < 500 mV),
VS = (VDD – GND) = 0 V- Maximum at 25°C: ±600 fA
- Maximum at 85°C: ±6.5 pA
- pH Buffer Input Offset Voltage: ±200 µV
- pH Buffer Input Offset Voltage Drift: ±2.5 µV/°C
- Supply Current: 50 µA
- Supply Voltage: 1.8 V to 5.5 V
- Operating Temperature Range: –40°C to 125°C
- Package: 16-Pin TSSOP
The LMP91200 device is a sensor AFE for use in low-power, analytical-sensing applications. The LMP91200 is designed for 2-electrode sensors. This device provides all of the functionality needed to detect changes based on a delta voltage at the sensor. Optimized for low-power applications, the LMP91200 works over a voltage range of 1.8 V to 5.5 V. With its extremely low input bias current it is optimized for use with pH sensors. Also, in absence of supply voltage the very low input bias current reduces degradation of the pH probe when connected to the LMP91200. Two guard pins provide support for high parasitic impedance wiring. Depending on the configuration, total current consumption for the device is 50 µA while measuring pH. Available in a 16-pin TSSOP package, the LMP91200 operates from –40°C to +125°C.
Technische Dokumentation
Typ | Titel | Datum | ||
---|---|---|---|---|
* | Data sheet | LMP91200 Configurable AFE for Low Power Chemical Sensing Apps datasheet (Rev. E) | 29 Feb 2016 | |
Technical article | What can we learn for IIoT from the man who invented the Web? | PDF | HTML | 12 Jan 2016 | |
Application note | AN-2254 MSP430 Interface to LMP91200 Code Library (Rev. A) | 01 Mai 2013 | ||
More literature | Sensor Analog Front Ends Brochure | 30 Okt 2012 | ||
EVM User's guide | LMP91200 Sensor AFE Evaluation Board User's Guide (Rev. A) | 30 Mai 2012 | ||
EVM User's guide | LMP91200 Sensor AFE Evaluation Board User's Guide | 07 Mai 2012 |
Design und Entwicklung
Weitere Bedingungen oder erforderliche Ressourcen enthält gegebenenfalls die Detailseite, die Sie durch Klicken auf einen der unten stehenden Titel erreichen.
LMP91200 TINA-TI Transient Spice Model (Rev. A)
TIDA-00561 — Drahtloser pH-Sensor-Transmitter (DevPack für SensorTag) – Referenzdesign
Gehäuse | Pins | CAD-Symbole, Footprints und 3D-Modelle |
---|---|---|
TSSOP (PW) | 16 | Ultra Librarian |
Bestellen & Qualität
- RoHS
- REACH
- Bausteinkennzeichnung
- Blei-Finish/Ball-Material
- MSL-Rating / Spitzenrückfluss
- MTBF-/FIT-Schätzungen
- Materialinhalt
- Qualifikationszusammenfassung
- Kontinuierliches Zuverlässigkeitsmonitoring
- Werksstandort
- Montagestandort
Empfohlene Produkte können Parameter, Evaluierungsmodule oder Referenzdesigns zu diesem TI-Produkt beinhalten.
Support und Schulungen
TI E2E™-Foren mit technischem Support von TI-Ingenieuren
Inhalte werden ohne Gewähr von TI und der Community bereitgestellt. Sie stellen keine Spezifikationen von TI dar. Siehe Nutzungsbedingungen.
Bei Fragen zu den Themen Qualität, Gehäuse oder Bestellung von TI-Produkten siehe TI-Support.