Function Differential Additive RMS jitter (Typ) (fs) 111 Output frequency (Max) (MHz) 1100 Number of outputs 10 Output supply voltage (V) 2.5 Core supply voltage (V) 2.5 Output skew (ps) 50 Features 1:10 fanout, Individual output enable control Operating temperature range (C) -40 to 85 Rating Catalog Output type LVDS Input type LVDS
Function Differential Additive RMS jitter (Typ) (fs) 111 Output frequency (Max) (MHz) 1100 Number of outputs 10 Output supply voltage (V) 2.5 Core supply voltage (V) 2.5 Output skew (ps) 50 Features 1:10 fanout, Individual output enable control Operating temperature range (C) -40 to 85 Rating Catalog Output type LVDS Input type LVDS
LQFP (VF) 32 49 mm² 7 x 7 VQFN (RHB) 32 25 mm² 5.0 x 5.0
  • Low-Output Skew <30 ps (Typical) for Clock-Distribution Applications
  • Distributes One Differential Clock Input to 10 LVDS Differential Clock Outputs
  • VCC Range: 2.5 V ±5%
  • Typical Signaling Rate Capability of Up to 1.1 GHz
  • Configurable Register (SI/CK) Individually Enables Disables Outputs, Selectable CLK0, CLK0 or CLK1, CLK1 Inputs
  • Full Rail-to-Rail Common-Mode Input Range
  • Receiver Input Threshold: ±100 mV
  • Available in 32-Pin LQFP and VQFN Package
  • Fail-Safe I/O-Pins for VDD = 0 V (Power Down)
  • Low-Output Skew <30 ps (Typical) for Clock-Distribution Applications
  • Distributes One Differential Clock Input to 10 LVDS Differential Clock Outputs
  • VCC Range: 2.5 V ±5%
  • Typical Signaling Rate Capability of Up to 1.1 GHz
  • Configurable Register (SI/CK) Individually Enables Disables Outputs, Selectable CLK0, CLK0 or CLK1, CLK1 Inputs
  • Full Rail-to-Rail Common-Mode Input Range
  • Receiver Input Threshold: ±100 mV
  • Available in 32-Pin LQFP and VQFN Package
  • Fail-Safe I/O-Pins for VDD = 0 V (Power Down)

The CDCLVD110A clock driver distributes one pair of differential LVDS clock inputs (either CLK0 or CLK1) to 10 pairs of differential clock outputs (Q0 to Q9) with minimum skew for clock distribution. The CDCLVD110A is specifically designed to drive 50-Ω transmission lines.

When the control enable is high (EN = 1), the 10 differential outputs are programmable in that each output can be individually enabled or disabled
(3-stated) according to the first 10 bits loaded into the shift register. Once the shift register is loaded, the last bit selects either CLK0 or CLK1 as the clock input. However, when EN = 0, the outputs are not programmable and all outputs are enabled.

The CDCLVD110A has an improved start-up circuit that minimizes enabling time in AC- and DC-coupled systems.

The CDCLVD110A is characterized for operation from –40°C to 85°C.

The CDCLVD110A clock driver distributes one pair of differential LVDS clock inputs (either CLK0 or CLK1) to 10 pairs of differential clock outputs (Q0 to Q9) with minimum skew for clock distribution. The CDCLVD110A is specifically designed to drive 50-Ω transmission lines.

When the control enable is high (EN = 1), the 10 differential outputs are programmable in that each output can be individually enabled or disabled
(3-stated) according to the first 10 bits loaded into the shift register. Once the shift register is loaded, the last bit selects either CLK0 or CLK1 as the clock input. However, when EN = 0, the outputs are not programmable and all outputs are enabled.

The CDCLVD110A has an improved start-up circuit that minimizes enabling time in AC- and DC-coupled systems.

The CDCLVD110A is characterized for operation from –40°C to 85°C.

ダウンロード

お客様が関心を持ちそうな類似製品

open-in-new 製品の比較
比較対象デバイスと類似の機能。
LMK00301 アクティブ 3GHz、10 出力、差動ファンアウト・バッファ / レベル・シフタ Ultra low additive jitter, 10 output universal differential buffer

技術資料

star =TI が選定したこの製品の主要ドキュメント
結果が見つかりませんでした。検索条件をクリアして、もう一度検索を行ってください。
1 をすべて表示
種類 タイトル 最新の英語版をダウンロード 日付
* データシート CDCLVD110A Programmable Low-Voltage 1:10 LVDS Clock Driver データシート (Rev. D) PDF | HTML 2016年 12月 12日

設計および開発

その他のアイテムや必要なリソースを参照するには、以下のタイトルをクリックして詳細ページを表示してください。

シミュレーション・モデル

CDCLVD110A IBIS Software

SCAC099.ZIP (13 KB) - IBIS Model
設計ツール

CLOCK-TREE-ARCHITECT

Clock tree architect プログラミング・ソフトウェア

Clock tree architect はクロック・ツリーの合成ツールであり、開発中システムの要件に基づいてクロック・ツリー・ソリューションを生成する方法で、お客様の設計プロセスの効率化に貢献します。このツールは、多様なクロック供給製品を収録した包括的なデータベースからデータを抽出し、システム・レベルのマルチチップ・クロック供給ソリューションを生成します。
シミュレーション・ツール

PSPICE-FOR-TI — TI Design / シミュレーション・ツール向け PSpice®

PSpice® for TI は、各種アナログ回路の機能評価に役立つ、設計とシミュレーション向けの環境です。設計とシミュレーションに適したこのフル機能スイートは、Cadence® のアナログ分析エンジンを使用しています。PSpice for TI は無償で使用でき、アナログや電源に関する TI の製品ラインアップを対象とする、業界でも有数の大規模なモデル・ライブラリが付属しているほか、選択された一部のアナログ動作モデルも利用できます。

設計とシミュレーション向けの環境である PSpice for TI (...)
パッケージ ピン数 ダウンロード
LQFP (VF) 32 オプションの表示
VQFN (RHB) 32 オプションの表示

購入と品質

記載されている情報:
  • RoHS
  • REACH
  • デバイスのマーキング
  • リード端子の仕上げ / ボールの原材料
  • MSL rating / リフローピーク温度
  • MTBF/FIT 推定値
  • 材料 (内容)
  • 認定試験結果
  • 継続的な信頼性モニタ試験結果

推奨製品には、この TI 製品に関連するパラメータ、評価基板、またはリファレンス・デザインが存在する可能性があります。

サポートとトレーニング

TI E2E™ Forums (英語) では、TI のエンジニアからの技術サポートが活用できます

コンテンツは、TI 投稿者やコミュニティ投稿者によって「現状のまま」提供されるもので、TI による仕様の追加を意図するものではありません。使用条件をご確認ください。

TI 製品の品質、パッケージ、ご注文に関するお問い合わせは、TI サポートをご覧ください。​​​​​​​​​​​​​​

ビデオ