전력 관리 AC/DC 스위칭 레귤레이터 AC/DC 컨트롤러

주파수 폴드백 전류 모드 PWM 컨트롤러, 0°C~70°C

UCC3884은(는) 새 설계에 권장하지 않습니다.
이 제품은 기존 고객을 위해 계속 제공됩니다. 새로운 설계는 대체 제품을 고려해야 합니다.
open-in-new 대안 비교
비교 대상 장치와 유사한 기능
UCC2897A 활성 P 채널 클램프 FET 및 라인 OV 보호를 지원하는 110V 능동 클램프 전류 모드 PWM 컨트롤러 Wider temperature range

제품 상세 정보

Topology Boost, Flyback Control mode Current Features Error amplifier, Multi-topology, Soft start, Synchronization pin Duty cycle (max) (%) 78
Topology Boost, Flyback Control mode Current Features Error amplifier, Multi-topology, Soft start, Synchronization pin Duty cycle (max) (%) 78
SOIC (D) 16 59.4 mm² 9.9 x 6
  • Frequency Foldback Reduces Operating Frequency Under Fault Conditions
  • Accurate Programmable Volt-Second Clamp
  • Programmable Maximum Duty Cycle Clamp
  • Oscillator Synchronization
  • Overcurrent Protection
  • Shutdown With Full Soft Start
  • Wide Gain Bandwidth Amplifier (GBW > 2.5 MHz)
  • Current Mode Operation
  • Precision 5-V Reference
  • Frequency Foldback Reduces Operating Frequency Under Fault Conditions
  • Accurate Programmable Volt-Second Clamp
  • Programmable Maximum Duty Cycle Clamp
  • Oscillator Synchronization
  • Overcurrent Protection
  • Shutdown With Full Soft Start
  • Wide Gain Bandwidth Amplifier (GBW > 2.5 MHz)
  • Current Mode Operation
  • Precision 5-V Reference

The UCC3884 is a high performance current mode PWM controller intended for single ended switch mode power supplies. The chip implements a frequency foldback scheme that decreases the oscillator frequency as the output voltage falls below a programmed value. This technique decreases the average output current sourced into a low impedance load which can occur during an output short circuit or overload condition. Excessive short circuit current is more prevalent in high frequency converters where the propagation delay and switch turn-off time forces a minimum attainable duty cycle. An accurate volt-second clamp limits the duty cycle during line or load transient conditions which could otherwise saturate the transformer. The volt-second clamp may also be used with an external overvoltage protection circuit to handle fault conditions such as current sense disconnect or current transformer saturation.

The frequency foldback, volt-second clamp, cycle-by-cycle current limit, and overcurrent shutdown provide a rich set of protection features for use in peak current-mode pulse width modulators.

The UCC3884 is a high performance current mode PWM controller intended for single ended switch mode power supplies. The chip implements a frequency foldback scheme that decreases the oscillator frequency as the output voltage falls below a programmed value. This technique decreases the average output current sourced into a low impedance load which can occur during an output short circuit or overload condition. Excessive short circuit current is more prevalent in high frequency converters where the propagation delay and switch turn-off time forces a minimum attainable duty cycle. An accurate volt-second clamp limits the duty cycle during line or load transient conditions which could otherwise saturate the transformer. The volt-second clamp may also be used with an external overvoltage protection circuit to handle fault conditions such as current sense disconnect or current transformer saturation.

The frequency foldback, volt-second clamp, cycle-by-cycle current limit, and overcurrent shutdown provide a rich set of protection features for use in peak current-mode pulse width modulators.

다운로드

기술 자료

star =TI에서 선정한 이 제품의 인기 문서
검색된 결과가 없습니다. 검색어를 지우고 다시 시도하세요.
1개 모두 보기
상위 문서 유형 직함 형식 옵션 날짜
* Data sheet Frequency Foldback Current Mode PWM Controller datasheet (Rev. C) 2008/11/20

주문 및 품질

포함된 정보:
  • RoHS
  • REACH
  • 디바이스 마킹
  • 납 마감/볼 재질
  • MSL 등급/피크 리플로우
  • MTBF/FIT 예측
  • 물질 성분
  • 인증 요약
  • 지속적인 신뢰성 모니터링
포함된 정보:
  • 팹 위치
  • 조립 위치