產品詳細資料

PGA/VGA PGA Number of channels 2 Vs (min) (V) 2.7 Vs (max) (V) 5.5 Input type Differential Output type Single-ended Input offset drift (±) (typ) (µV/°C) 0.2 Interface type 1-wire, Analog 2 Wire, UART Noise at 1 kHz (typ) (V√Hz) 0.00000021 BW at Acl (MHz) 2 Acl, min spec gain (V/V) 4 Voltage gain (max) (V/V) 61.2 Gain (max) (dB) 42 Architecture CMOS Features Temperature sensing Vos (offset voltage at 25°C) (typ) (mV) 0.003 Input voltage noise (typ) (µV√Hz) 0.21 Slew rate (typ) (V/µs) 0.5 Iq per channel (typ) (mA) 1.2 Gain error (typ) (%) 0.3 Gain drift (max) (ppm/°C) 10 Rating Catalog Operating temperature range (°C) -40 to 125
PGA/VGA PGA Number of channels 2 Vs (min) (V) 2.7 Vs (max) (V) 5.5 Input type Differential Output type Single-ended Input offset drift (±) (typ) (µV/°C) 0.2 Interface type 1-wire, Analog 2 Wire, UART Noise at 1 kHz (typ) (V√Hz) 0.00000021 BW at Acl (MHz) 2 Acl, min spec gain (V/V) 4 Voltage gain (max) (V/V) 61.2 Gain (max) (dB) 42 Architecture CMOS Features Temperature sensing Vos (offset voltage at 25°C) (typ) (mV) 0.003 Input voltage noise (typ) (µV√Hz) 0.21 Slew rate (typ) (V/µs) 0.5 Iq per channel (typ) (mA) 1.2 Gain error (typ) (%) 0.3 Gain drift (max) (ppm/°C) 10 Rating Catalog Operating temperature range (°C) -40 to 125
TSSOP (PW) 16 32 mm² (5 mm × 6.4 mm)
  • Complete Bridge Sensor Conditioner
  • Voltage Output: Ratiometric or Absolute
  • Digital Cal: No Potentiometers/Sensor Trims
  • Sensor Error Compensation
    • Span, Offset, and Temperature Drifts
  • Low Error, Time-Stable
  • Sensor Linearization Circuitry
  • Temperature Sense: Internal or External
  • Calibration Lookup Table Logic
    • Uses External EEPROM (SOT23-5)
  • Over/Under-Scale Limiting
  • Sensor Fault Detection
  • +2.7V TO +5.5V Operation
  • –40°C to +125°C Operation
  • Small TSSOP-16 Package
  • APPLICATIONS
    • Bridge Sensors
    • Remote 4-20mA Transmitters
    • Strain, Load, and Weigh Scales
    • Automotive Sensors
  • APPLICATIONS
    • Hardware Designer’s Kit (PGA309EVM)
      • Temperature Eval of PGA309 + Sensor
      • Full Programming of PGA309
      • Sensor Compensation Analysis Tool
  • All other trademarks are the property of their respective owners.

    • Complete Bridge Sensor Conditioner
    • Voltage Output: Ratiometric or Absolute
    • Digital Cal: No Potentiometers/Sensor Trims
    • Sensor Error Compensation
      • Span, Offset, and Temperature Drifts
    • Low Error, Time-Stable
    • Sensor Linearization Circuitry
    • Temperature Sense: Internal or External
    • Calibration Lookup Table Logic
      • Uses External EEPROM (SOT23-5)
    • Over/Under-Scale Limiting
    • Sensor Fault Detection
    • +2.7V TO +5.5V Operation
    • –40°C to +125°C Operation
    • Small TSSOP-16 Package
    • APPLICATIONS
      • Bridge Sensors
      • Remote 4-20mA Transmitters
      • Strain, Load, and Weigh Scales
      • Automotive Sensors
  • APPLICATIONS
    • Hardware Designer’s Kit (PGA309EVM)
      • Temperature Eval of PGA309 + Sensor
      • Full Programming of PGA309
      • Sensor Compensation Analysis Tool
  • All other trademarks are the property of their respective owners.

    The PGA309 is a programmable analog signal conditioner designed for bridge sensors. The analog signal path amplifies the sensor signal and provides digital calibration for zero, span, zero drift, span drift, and sensor linearization errors with applied stress (pressure, strain, etc.). The calibration is done via a One-Wire digital serial interface or through a Two-Wire industry-standard connection. The calibration parameters are stored in external nonvolatile memory (typically SOT23-5) to eliminate manual trimming and achieve long-term stability.

    The all-analog signal path contains a 2x2 input multiplexer (mux), auto-zero programmable-gain instrumentation amplifier, linearization circuit, voltage reference, internal oscillator, control logic, and an output amplifier. Programmable level shifting compensates for sensor dc offsets.

    The core of the PGA309 is the precision, low-drift, no 1/f noise Front-End PGA (Programmable Gain Amplifier). The overall gain of the Front-End PGA + Output Amplifier can be adjusted from 2.7V/V to 1152V/V. The polarity of the inputs can be switched through the input mux to accommodate sensors with unknown polarity output. The Fault Monitor circuit detects and signals sensor burnout, overload, and system fault conditions.

    For detailed application information, see the PGA309 User's Guide (SBOU024) available for download at www.ti.com.

    The PGA309 is a programmable analog signal conditioner designed for bridge sensors. The analog signal path amplifies the sensor signal and provides digital calibration for zero, span, zero drift, span drift, and sensor linearization errors with applied stress (pressure, strain, etc.). The calibration is done via a One-Wire digital serial interface or through a Two-Wire industry-standard connection. The calibration parameters are stored in external nonvolatile memory (typically SOT23-5) to eliminate manual trimming and achieve long-term stability.

    The all-analog signal path contains a 2x2 input multiplexer (mux), auto-zero programmable-gain instrumentation amplifier, linearization circuit, voltage reference, internal oscillator, control logic, and an output amplifier. Programmable level shifting compensates for sensor dc offsets.

    The core of the PGA309 is the precision, low-drift, no 1/f noise Front-End PGA (Programmable Gain Amplifier). The overall gain of the Front-End PGA + Output Amplifier can be adjusted from 2.7V/V to 1152V/V. The polarity of the inputs can be switched through the input mux to accommodate sensors with unknown polarity output. The Fault Monitor circuit detects and signals sensor burnout, overload, and system fault conditions.

    For detailed application information, see the PGA309 User's Guide (SBOU024) available for download at www.ti.com.

    下載 觀看有字幕稿的影片 影片

    您可能會感興趣的類似產品

    open-in-new 比較替代產品
    功能相同,但針腳輸出與所比較的裝置不同。
    PGA113 現行 具 2 通道多工器的零漂移、100-µV 偏移、12-nV/√Hz 雜訊、RRO (範圍增益) 可編程增益放大器 PGA113 is a similar device but not the same functionality, offering wider gain range, 4 calibration channels, 2 channel MUX, and SPI interface

    技術文件

    找不到結果。請清除您的搜尋條件,然後再試一次。
    檢視所有 16
    重要文件 類型 標題 格式選項 下載最新的英文版本 日期
    * 資料表 Voltage Output Programmable Sensor Conditioner datasheet (Rev. C) 2011/1/14
    使用指南 PGA309 User's Guide (Rev. C) PDF | HTML 2023/7/28
    Application brief How to Select Amplifiers for Pressure Transmitter Applications (Rev. B) PDF | HTML 2023/2/14
    Application brief Multichannel Analog Input Modules for PLC Equipment 2019/1/4
    類比設計期刊 Ratiometric measurement in the context of LVDT-sensor signal conditioning 2016/7/21
    類比設計期刊 4Q 2011 Issue Analog Applications Journal 2011/11/9
    類比設計期刊 Analog linearization of resistance temperature detectors 2011/11/9
    EVM User's guide Multi-Cal-PGA309 System User Guide 2011/4/27
    使用指南 Multi-Cal-Master User's Guide 2010/8/22
    使用指南 Multi-Cal-Test Users Guide 2010/8/22
    應用說明 Using the XTR115 with the PGA309 to Generate 4mA to 20mA Output (Rev. B) 2006/4/20
    應用說明 PGA309 Quick Start System Reference Guide (Rev. C) 2006/1/13
    應用說明 PGA309 Noise Filtering (Rev. A) 2005/11/28
    應用說明 Practical Technique for Minimizing the Number of Measurements in Sensor Signal 2005/6/28
    應用說明 PGA309 Microcontroller Application 2005/6/7
    使用指南 Using PGA309 for Sensor Compensation 2004/3/11

    設計與開發

    如需其他條款或必要資源,請按一下下方的任何標題以檢視詳細頁面 (如有)。

    開發板

    MULTI-CAL-SYSTEM — Multi-Cal-System 基礎入門套件

    The Multi-Cal-System is a system of evaluation modules and accessories that can be used to calibrate multiple PGA308 sensor modules. The Multi-Cal-System can be configured to calibrate from 8 to 64 PGA308s simultaneously. The key component of the Multi-Cal-System is the Multi-Cal-System Starter (...)

    使用指南: PDF
    支援產品和硬體
    有庫存
    限制:
    ??asset.out-of-stock-ti_zh_TW??
    無法提供
    開發板

    PGA309EVM-USB — PGA309 評估模組

    The PGA309EVM-USB key hardware consists of two boards, PGA309 Test Board and USB DAQ Platform. The PGA309 Test Board contains the PGA309, terminal strips for external connections, several jumpers for device configuration, and support circuitry. The PGA309 Test Board can be used to fully test your (...)

    使用指南: PDF
    支援產品和硬體
    有庫存
    限制:
    ??asset.out-of-stock-ti_zh_TW??
    無法提供
    開發板

    SENSOREMULATOREVM — SensorEmulatorEVM 評估模組

    The SensorEmulatorEVM provides a complete system for strain and temperature emulation of voltage-excited bridge sensors. The SensorEmulatorEVM uses rotary selector switches and potentiometers to emulate the operation of a voltage-excited Wheatstone resistive bridge sensor at discrete operating (...)

    支援產品和硬體
    有庫存
    限制:
    ??asset.out-of-stock-ti_zh_TW??
    無法提供
    支援軟體

    SBOC320 — PGA309EVM-USB Software

    支援產品和硬體
    支援軟體

    SBOC394 — PGA309EVM-USB Source Code

    支援產品和硬體
    支援軟體

    SBOC401 — Multi-Cal-PGA309 System Software

    支援產品和硬體
    計算工具

    SBOC065 — Generate Simulated Values

    支援產品和硬體
    計算工具

    SBOC132 — PGA309 Calculator Source Code

    支援產品和硬體
    計算工具

    SLOR088 — PGA309EVM Software (Rev 1.5.17) – Includes PGA309 Calculator Software

    支援產品和硬體
    計算工具

    SLVC073 — PGA309 Gain Calculator

    支援產品和硬體
    參考設計

    TIPD126 — 橋式感測器訊號調節器參考設計,具備電流環路輸出與 EMC 防護功能

    此橋式感測器調節模組可提供良好的穩壓電流輸出至接地參考負載。第一級採用混合訊號可編程增益放大器 (PGA),為差動橋式感測器電壓提供線性化與溫度補償。第二級將 PGA 輸出電壓轉換為電流,並透過標準 4mA 至 20mA 電流迴路進行傳輸。額外電路可保護模組免受靜電放電 (ESD)、電快速瞬變 (EFT)、輻射與傳導電磁干擾 (EMI) 以及雷擊突波的影響。

    支援產品和硬體
    封裝 針腳 CAD 符號、佔位空間與 3D 模型
    TSSOP (PW) 16 Ultra Librarian

    訂購與品質

    支援與培訓

    內含 TI 工程師技術支援的 TI E2E™ 論壇

    內容係由 TI 和社群貢獻者依「現狀」提供,且不構成 TI 規範。檢視使用條款

    若有關於品質、封裝或訂購 TI 產品的問題,請參閱 TI 支援。​​​​​​​​​​​​​​

    影片