JAJSSE7 November   2023 DRV8214

PRODUCTION DATA  

  1.   1
  2. 特長
  3. アプリケーション
  4. 概要
  5. Revision History
  6. Device Comparison
  7. Pin Configuration and Functions
  8. Specifications
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings
    3. 7.3 Recommended Operating Conditions
    4. 7.4 Thermal Information
    5. 7.5 Electrical Characteristics
    6. 7.6 I2C Timing Requirements
    7. 7.7 Timing Diagrams
    8. 7.8 Typical Operating Characteristics
  9. Detailed Description
    1. 8.1 Overview
    2. 8.2 Functional Block Diagram
    3. 8.3 Feature Description
      1. 8.3.1 External Components
      2. 8.3.2 Summary of Features
      3. 8.3.3 Bridge Control
      4. 8.3.4 Current Sense and Regulation (IPROPI)
        1. 8.3.4.1 Current Sensing and Current Mirror Gain Selection
        2. 8.3.4.2 Current Regulation
          1. 8.3.4.2.1 Fixed Off-Time Current Regulation
          2. 8.3.4.2.2 Cycle-By-Cycle Current Regulation
      5. 8.3.5 Stall Detection
      6. 8.3.6 Ripple Counting
        1. 8.3.6.1 Ripple Counting Parameters
          1. 8.3.6.1.1  Motor Resistance Inverse
          2. 8.3.6.1.2  Motor Resistance Inverse Scale
          3. 8.3.6.1.3  KMC Scaling Factor
          4. 8.3.6.1.4  KMC
          5. 8.3.6.1.5  Filter Damping Constant
          6. 8.3.6.1.6  Filter Input Scaling Factor
          7. 8.3.6.1.7  Ripple Count Threshold
          8. 8.3.6.1.8  Ripple Count Threshold Scale
          9. 8.3.6.1.9  T_MECH_FLT
          10. 8.3.6.1.10 VSNS_SEL
          11. 8.3.6.1.11 Error Correction
            1. 8.3.6.1.11.1 EC_FALSE_PER
            2. 8.3.6.1.11.2 EC_MISS_PER
        2. 8.3.6.2 RC_OUT Output
        3. 8.3.6.3 Ripple Counting with nFAULT
      7. 8.3.7 Motor Voltage and Speed Regulation
        1. 8.3.7.1 Internal Bridge Control
        2. 8.3.7.2 Setting Speed/Voltage Regulation Parameters
          1. 8.3.7.2.1 Speed and Voltage Set
          2. 8.3.7.2.2 Speed Scaling Factor
        3. 8.3.7.3 Soft-Start and Soft-Stop
          1. 8.3.7.3.1 TINRUSH
      8. 8.3.8 Protection Circuits
        1. 8.3.8.1 Overcurrent Protection (OCP)
        2. 8.3.8.2 Thermal Shutdown (TSD)
        3. 8.3.8.3 VCC Undervoltage Lockout (UVLO)
        4. 8.3.8.4 Overvoltage Protection (OVP)
        5. 8.3.8.5 nFAULT Output
    4. 8.4 Device Functional Modes
      1. 8.4.1 Active Mode
      2. 8.4.2 Low-Power Sleep Mode
      3. 8.4.3 Fault Mode
    5. 8.5 Programming
      1. 8.5.1 I2C Communication
        1. 8.5.1.1 I2C Write
        2. 8.5.1.2 I2C Read
    6. 8.6 Register Map
      1. 8.6.1 DRV8214_STATUS Registers
      2. 8.6.2 DRV8214_CONFIG Registers
      3. 8.6.3 DRV8214_CTRL Registers
  10. Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application: Brushed DC Motor
      1. 9.2.1 Design Requirements
      2. 9.2.2 Stall Detection
        1. 9.2.2.1 Application Description
          1. 9.2.2.1.1 Stall Detection Timing
          2. 9.2.2.1.2 Hardware Stall Threshold Selection
      3. 9.2.3 Ripple Counting Application
        1. 9.2.3.1 Tuning Ripple Counting Parameters
          1. 9.2.3.1.1 Resistance Parameters
          2. 9.2.3.1.2 KMC and KMC_SCALE
            1. 9.2.3.1.2.1 Case I
            2. 9.2.3.1.2.2 Case II
              1. 9.2.3.1.2.2.1 Method 1: Tuning from Scratch
                1. 9.2.3.1.2.2.1.1 Tuning KMC_SCALE
                2. 9.2.3.1.2.2.1.2 Tuning KMC
              2. 9.2.3.1.2.2.2 Method 2: Using the Proportionality factor
                1. 9.2.3.1.2.2.2.1 Working Example
          3. 9.2.3.1.3 Advanced Parameters
            1. 9.2.3.1.3.1 Filter Constants
              1. 9.2.3.1.3.1.1 FLT_GAIN_SEL
              2. 9.2.3.1.3.1.2 FLT_K
            2. 9.2.3.1.3.2 T_MECH_FLT
            3. 9.2.3.1.3.3 VSNS_SEL
            4. 9.2.3.1.3.4 Additional Error Corrector Parameters
              1. 9.2.3.1.3.4.1 EC_FALSE_PER
              2. 9.2.3.1.3.4.2 EC_MISS_PER
      4. 9.2.4 Motor Voltage
      5. 9.2.5 Motor Current
      6. 9.2.6 Application Curves
  11. 10Power Supply Recommendations
    1. 10.1 Bulk Capacitance
  12. 11Layout
    1. 11.1 Layout Guidelines
  13. 12Mechanical, Packaging, and Orderable Information
    1. 12.1 Tape and Reel Information

パッケージ・オプション

メカニカル・データ(パッケージ|ピン)
サーマルパッド・メカニカル・データ
発注情報
Error Correction

Error correction involves the use of two registers, DIS_EC and EC_PULSE_DIS.

DIS_EC is used to enable/disable the error correction block shown in Figure 8-12. Table 8-18 shows the settings for DIS_EC.

Table 8-18 Settings for DIS_EC
Bit Description
0b Error Correction block is enabled.
1b Error Correction block is disabled.

EC_PULSE_DIS is used to enable/disable the output of the Error Correction block when the Error Correction block is enabled. Table 8-19 describes the settings of EC_PULSE_DIS in detail.

Table 8-19 Settings for EC_PULSE_DIS
Bit Status of Error Correction block output
0b

Output follows settings for DIS_EC as displayed in Table 8-18. If DIS_EC is set to 0b, RC_OUT continues to output pulses even when the motor is:

  • Disconnected,
  • Connected but not rotating, or
  • Stalled (depending on the settings for SMODE), if ripple counting is enabled.

Please note that the Error Correction block is active in this setting.

1b

Output is disabled if the following two conditions are met:

  1. Error corrector adds 12 consecutive pulses, and
  2. The bandpass filter does not give any pulse output during the time period of the 12 consecutive pulses.

Please note that the Error Correction block is active in this setting.

Table 8-20 summarizes the settings described above.

Table 8-20 Summary of Error Correction
DIS_EC EC_PULSE_DIS Error Corrector Status Output Pulse Status
0b 0b Enabled Pulse train output from RC_OUT
0b 1b Enabled No pulses only if Error Corrector adds 12 consecutive pulses and bandpass filter gives no output.
1b X Disabled No Pulses