SNAS758A February 2025 – June 2025 HDC3120
PRODUCTION DATA
Refer to the PDF data sheet for device specific package drawings
The HDC3120 includes a power-on reset (POR) function that controls the output voltage at power up. After the VDD supply has been established (VDD> VPOR), a POR event is issued. The POR causes the device to load the default settings from the memory and subsequently performs temperature and humidity measurements.
During the first humidity and temperature measurement, the DAC outputs are driven to a default level of 0.1* VDD. Each DAC channel remains at the default voltage level until the measurement is completed, which takes approximately RHPUR for the humidity measurement and TPUR for the temperature measurement. After the measurement is completed, the DAC outputs are driven to the voltage level corresponding to the measured humidity and temperature values. Figure 7-3 shows an example of the HDC3120 power-up behavior.
Note the POR circuit requires specific supply levels to discharge the internal capacitors and to reset the device on power up, as indicated in Figure 7-4. To initiate a POR event, VDD must be below the corresponding low thresholds (VBOR) for a duration of at least tRESET_NPW. If VDD remains above the specified high threshold (VPOR), a POR event does not occur. When the VDD drops below the high threshold VPOR but remain over the lower one (VBOR), the device is situated in an undefined state, and does not necessarily reset under all specified temperature and power supply conditions.