SNAS758A February 2025 – June 2025 HDC3120
PRODUCTION DATA
Refer to the PDF data sheet for device specific package drawings
Prolonged operation at extremes (high or low) relative humidities and/or temperatures can temporarily shift the RH output. Long exposure outside the recommended operating conditions at both extreme humidity and temperature can temporarily or permanently offset the RH output.
The recommended humidity operating range is 0 to 100% RH (non-condensing) over –20°C to 80°C. Operating beyond these ranges, or prolonged operation at certain extremes within these ranges (e.g. 85%RH at 80°C) can lead to:
Gradual RH Offset: Extended exposure near 100% RH can temporarily shift readings.
Slow Recovery: Return to normal ambient conditions typically resolves offsets over hours or days.
Permanent Effects: Repeated or severe exposure can result in irreversible drift.