SLLSFF0 December   2021 TCAN1167-Q1

PRODUCTION DATA  

  1. Features
  2. Applications
  3. Description
  4. Revision History
  5. Description (continued)
  6. Pin Configurations and Functions
  7. Specifications
    1. 7.1 Absolute Maximum Ratings
    2. 7.2 ESD Ratings
    3. 7.3 ESD Ratings IEC Specification
    4. 7.4 Recomended Operating Conditions
    5. 7.5 Thermal Information
    6. 7.6 Power Supply Characteristics
    7. 7.7 Electrical Characteristics
    8. 7.8 Switching Characteristics
    9. 7.9 Typical Characteristics
  8. Parameter Measurement Information
  9. Detailed Description
    1. 9.1 Overview
    2. 9.2 Functional Block Diagram
    3. 9.3 Feature Description
      1. 9.3.1  VSUP Pin
      2. 9.3.2  VCCOUT Pin
      3. 9.3.3  Digital Inputs and Outputs
        1. 9.3.3.1 TXD Pin
        2. 9.3.3.2 RXD Pin
      4. 9.3.4  GND
      5. 9.3.5  INH Pin
      6. 9.3.6  WAKE Pin
      7. 9.3.7  nRST Pin
      8. 9.3.8  SDO
      9. 9.3.9  nCS Pin
      10. 9.3.10 SCLK
      11. 9.3.11 SDI
      12. 9.3.12 CAN Bus Pins
      13. 9.3.13 Local Faults
        1. 9.3.13.1 TXD Dominant Timeout (TXD DTO)
        2. 9.3.13.2 Thermal Shutdown (TSD)
        3. 9.3.13.3 Under/Over Voltage Lockout
        4. 9.3.13.4 Unpowered Devices
        5. 9.3.13.5 Floating Terminals
        6. 9.3.13.6 CAN Bus Short Circuit Current Limiting
        7. 9.3.13.7 Sleep Wake Error Timer
      14. 9.3.14 Watchdog
        1. 9.3.14.1 Watchdog Error Counter
        2. 9.3.14.2 Watchdog SPI Control Programming
        3. 9.3.14.3 Watchdog Timing
        4. 9.3.14.4 Question and Answer Watchdog
          1. 9.3.14.4.1 WD Question and Answer Basic information
          2. 9.3.14.4.2 Question and Answer Register and Settings
          3. 9.3.14.4.3 WD Question and Answer Value Generation
        5. 9.3.14.5 Question and Answer WD Example
          1. 9.3.14.5.1 Example configuration for desired behavior
          2. 9.3.14.5.2 Example of performing a question and answer sequence
      15. 9.3.15 Bus Fault Detection and Communication
    4. 9.4 Device Functional Modes
      1. 9.4.1 Operating Mode Description
        1. 9.4.1.1 Normal Mode
        2. 9.4.1.2 Silent Mode
        3. 9.4.1.3 Standby Mode
        4. 9.4.1.4 Sleep Mode
          1. 9.4.1.4.1 Remote Wake Request via Wake-Up Pattern (WUP)
          2. 9.4.1.4.2 Local Wake-Up (LWU) via WAKE Input Terminal
        5. 9.4.1.5 Reset Mode
        6. 9.4.1.6 Fail-safe Mode
      2. 9.4.2 CAN Transceiver
        1. 9.4.2.1 CAN Transceiver Operation
        2. 9.4.2.2 CAN Transceiver Modes
          1. 9.4.2.2.1 CAN Off Mode
          2. 9.4.2.2.2 CAN Autonomous: Inactive and Active
          3. 9.4.2.2.3 CAN Active
        3. 9.4.2.3 Driver and Receiver Function Tables
        4. 9.4.2.4 CAN Bus States
    5. 9.5 Programming
      1. 9.5.1 Serial Peripheral Interface (SPI) Communication
      2. 9.5.2 Serial Clock Input (SCLK)
      3. 9.5.3 Serial Data Input (SDI)
      4. 9.5.4 Serial Data Output (SDO)
      5. 9.5.5 Chip Select Not (nCS)
      6. 9.5.6 Registers
        1. 9.5.6.1  DEVICE_ID_y Register (Address = 0h + formula) [reset = xxh]
        2. 9.5.6.2  REV_ID_MAJOR Register (Address = 8h) [reset = 00h]
        3. 9.5.6.3  REV_ID_MINOR Register (Address = 9h) [reset = 00h]
        4. 9.5.6.4  SPI_RSVD_x Register (Address = Ah + formula) [reset = 00h]
        5. 9.5.6.5  Scratch_Pad_SPI Register (Address = Fh) [reset = 00h]
        6. 9.5.6.6  MODE_CNTRL Register (Address = 10h) [reset = 04h]
        7. 9.5.6.7  WD_CONFIG_1 Register (Address = 13h) [reset = 54h]
        8. 9.5.6.8  WD_CONFIG_2 Register (Address = 14h) [reset = 02h]
        9. 9.5.6.9  WD_INPUT_TRIG Register (Address = 15h) [reset = 00h]
        10. 9.5.6.10 WD_QA_CONFIG Register (Address = 2Dh) [reset = 0h]
        11. 9.5.6.11 WD_QA_ANSWER Register (Address = 2Eh) [reset = 0h]
        12. 9.5.6.12 WD_QA_QUESTION Register (Address = 2Fh) [reset = 0h]
        13. 9.5.6.13 STATUS (address = 40h) [reset = 00h]
        14. 9.5.6.14 INT_GLOBAL Register (Address = 50h) [reset = 0h]
        15. 9.5.6.15 INT_1 Register (Address = 51h) [reset = 0h]
        16. 9.5.6.16 INT_2 Register (Address = 52h) [reset = 40h]
        17. 9.5.6.17 INT_3 Register (Address 53h) [reset = 0h]
        18. 9.5.6.18 INT_CANBUS Register (Address = 54h) [reset = 0h]
        19. 9.5.6.19 INT_ENABLE_1 Register (Address = 56h) [reset = F3h]
        20. 9.5.6.20 INT_ENABLE_2 Register (Address = 57h) [reset = 3Fh]
        21. 9.5.6.21 INT_ENABLE_3 Register (Address =58h) [reset = 80h]
        22. 9.5.6.22 INT_ENABLE_CANBUS Register (Address = 59h) [reset = 7Fh]
        23. 9.5.6.23 INT_RSVD_y Register (Address = 5Ah + formula) [reset = 00h]
  10. 10Application Information Disclaimer
    1. 10.1 Application Information
    2. 10.2 Typical Application
      1. 10.2.1 Design Requirements
        1. 10.2.1.1 Bus Loading, Length and Number of Nodes
      2. 10.2.2 Detailed Design Procedures
        1. 10.2.2.1 CAN Termination
    3. 10.3 Application Curves
  11. 11Power Supply Requirements
  12. 12Layout
    1. 12.1 Layout Guidelines
    2. 12.2 Layout Example
  13. 13Device and Documentation Support
    1. 13.1 Documentation Support
      1. 13.1.1 Related Documentation
    2. 13.2 Receiving Notification of Documentation Updates
    3. 13.3 Support Resources
    4. 13.4 Trademarks
    5. 13.5 Electrostatic Discharge Caution
    6. 13.6 Glossary
  14. 14Mechanical, Packaging, and Orderable Information

Package Options

Refer to the PDF data sheet for device specific package drawings

Mechanical Data (Package|Pins)
  • DMT|14
Thermal pad, mechanical data (Package|Pins)
Orderable Information
CAN Autonomous: Inactive and Active

When the CAN transceiver is in standby mode or sleep mode the CAN bias circuit is switched off and the transceiver moves to the autonomous inactive state. In the autonomous inactive state the CAN pins are biased to GND. When a valid wake-up event occurs the CAN bus is biased to 2.5 V. If the controller does not transition the TCAN1167-Q1 into normal mode before the tSILENCE timer expires, then the CAN biasing circuit is again switched off and the CAN pins are biased to ground.

The CAN transceiver switches to the CAN autonomous mode if any of the following conditions are met:

  • The TCAN1167-Q1 transitions from CAN off mode to CAN autonomous inactive

The CAN transceiver switches between the CAN autonomous inactive mode and CAN autonomous active mode if:

  • A valid wake-up event
  • The TCAN1167-Q1 transitions to normal mode and no undervoltage faults exist.

The CAN transceiver switches between the CAN autonomous active mode and CAN autonomous inactive mode if:

  • t > tSILENCE and the TCAN1167-Q1 transitions to standby mode, sleep mode, or fail-safe mode.