SLOS887G September 2014 – May 2025 TMP112-Q1 , TMP112D-Q1
PRODUCTION DATA
Figure 8-6 shows the step response of the TMP112-Q1/TMP112D-Q1 device to a submersion in an oil bath of 100°C from room temperature (27°C). The time-constant, or the time for the output to reach 63% of the input step, is 1.2s for both packages. The time-constant result depends on the printed circuit board (PCB) that the TMP112-Q1/TMP112D-Q1 device is mounted. For this test, the TMP112-Q1/TMP112D-Q1 device is soldered to a two-layer PCB that measured 0.5 inches × 0.5 inches.