When the Shutdown bit is set to 0b in the configuration register, the device operates in continuous conversion mode. Figure 7-3 shows the device in a continuous conversion cycle. In this mode, the device performs conversion at fixed periods and updates the temperature result register at the end of every conversion, The typical active conversion time is 11ms.
The Conversion_Rate[1:0] bits in the configuration register control the rate at which the conversions are performed. The device typically consumes 55µA during conversion and 0.85µA during the low power standby time. By decreasing the rate at which conversions are performed, the application can benefit from reduced average current consumption in continuous mode.
Use Equation 1 to calculate the average current in continuous mode.