SBOSAJ5 December 2024 TMP113
PRODUCTION DATA
Refer to the PDF data sheet for device specific package drawings
This register is used to configure the high temperature alert limit of the device. The limit is formatted in a 12-bit two's complement format with a LSB equal to 62.5m°C. The default value on start-up is 5000h or 80°C.
Return to Register Map.
| 15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
| THigh_Limit[11:4] | |||||||
| R/W-50h | |||||||
| 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
| THigh_Limit[3:0] | Reserved | ||||||
| R/W-0h | R-0000b | ||||||
| Bit | Field | Type | Reset | Description |
|---|---|---|---|---|
| 15:4 | THigh_Limit[11:0] | R/W | 500h | 12-bit temperature high limit setting. Temperature high limit is represented by a 12-bit, two's complement word with an LSB equal to 62.5m°C. The default setting for this is 80°C. |
| 3:0 | Reserved | R | 0000b | Reserved |