SCDS487A October 2025 – December 2025 TMUX4819 , TMUX4821
PRODUCTION DATA
The tON (VDD) time is defined as the time taken by the output of the device to rise 90% after the supply has risen past the supply threshold. The 90% measurement is used to provide the timing of the device turning on in the system. Figure 14-6 shows the setup used to measure turn on time, denoted by the symbol tON (VDD)