PRODUCTION DATA
Figure 6-6 and Table 6-2 describe how the turn-on and turn-off times of both LDOs (respectively) are controlled by setting the enable circuit (EN) and undervoltage lockout circuit (UVLOP and UVLON).
Figure 6-6 Simplified Turn-On
Control| POSITIVE INPUT VOLTAGE (VINP) | NEGATIVE INPUT VOLTAGE (VINN) | ENABLE STATUS | LDO STATUS | ACTIVE DISCHARGE |
|---|---|---|---|---|
| VINP ≥ VUVLOP | VINN ≤ VUVLON | EN = 1 | On | Off |
| EN = 0 | Off | On(1) | ||
| VINP ≥ VUVLOP | VINN > VUVLON | EN = Don't care | Off | On(1) |
| VINP < VUVLOP | VINN ≤ VUVLON | EN = Don't care | Off | On(1) |
| VINP < VUVLOP – VUVLOP(hys) | VINN > VUVLON – VUVLON(hys) | EN = Don't care | Off | On(1) |