SLAAEF5B March   2024  – June 2025 MSPM0G1505 , MSPM0G1506 , MSPM0G1507 , MSPM0G3506 , MSPM0G3507 , MSPM0H3216 , MSPM0L1303 , MSPM0L1304 , MSPM0L1304-Q1 , MSPM0L1305 , MSPM0L1305-Q1 , MSPM0L1306 , MSPM0L1306-Q1

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1Introduction
  5. 2Algorithm Introduction
    1. 2.1 Battery Basic Knowledge Introduction
    2. 2.2 Different SOCs and Used Technologies
      1. 2.2.1 NomAbsSoc Calculation
        1. 2.2.1.1 Coulometer With OCV Calibration
        2. 2.2.1.2 Data Fusion
        3. 2.2.1.3 Battery Model Filter
      2. 2.2.2 CusRltSoc Calculation
        1. 2.2.2.1 EmptySoc and FullSoc
        2. 2.2.2.2 Core Temperature Evaluation
      3. 2.2.3 SmoothRltSoc Calculation
    3. 2.3 Algorithm Overview
      1. 2.3.1 Voltage Gauge Introduction
      2. 2.3.2 Current Gauge Introduction
      3. 2.3.3 Capacity Learn Introduction
      4. 2.3.4 Mixing Introduction
  6. 3Gauge GUI Introduction
    1. 3.1 MCU COM Tool
    2. 3.2 SM COM Tool
    3. 3.3 Data Analysis Tool
  7. 4MSPM0 Gauge Evaluation Steps
    1. 4.1 Step 1: Hardware Preparation
    2. 4.2 Step 2: Get a Battery Model
      1. 4.2.1 Battery Test Pattern
      2. 4.2.2 Battery Model Generation
    3. 4.3 Step 3: Input Customized Configuration
    4. 4.4 Step 4: Evaluation
      1. 4.4.1 Detection Data Input Mode
      2. 4.4.2 Communication Data Input Mode
    5. 4.5 Step 5: Gauge Performance Check
      1. 4.5.1 Learning Cycles
      2. 4.5.2 SOC and SOH Accuracy Evaluation
  8. 5MSPM0 Gauge Solutions
    1. 5.1 MSPM0L1306 and 1 LiCO2 Battery
      1. 5.1.1 Hardware Setup Introduction
      2. 5.1.2 Software and Evaluation Introduction
      3. 5.1.3 Battery Test Cases
        1. 5.1.3.1 Performance Test
        2. 5.1.3.2 Current Consumption Test
    2. 5.2 MSPM0G3507, BQ76952 and 4 LiFePO4 Batteries
      1. 5.2.1 Hardware Setup Introduction
      2. 5.2.2 Software and Evaluation Introduction
      3. 5.2.3 Battery Test Cases
        1. 5.2.3.1 Performance Test 1 (Pulse Discharge)
        2. 5.2.3.2 Performance Test 2 (Load Change)
    3. 5.3 MSPM0L1306 and BQ76905
  9. 6Summary
  10. 7References
  11. 8Revision History

Step 4: Evaluation

Figure 4-10 shows different evaluation modes used for different conditions selected in Gauge_UserConfig.h.

 Gauge Mode Setting Figure 4-10 Gauge Mode Setting

For different output modes, UART_OUTPUT means enabling data output through universal asynchronous receiver or transmitter (UART). Then, users can observe the battery running parameters on the GUI through USB to tool. NO_OUTPUT means terminating the UART data output.

The different detection modes are detailed in the following section. Detection data input mode is the common used mode. All the algorithm input is from real data tested by AFE. The input data of the communication data input mode comes from the GUI and the one cycle time limitation lies on the UART communication speed.