SBAK035 January   2025 ADC168M102R-SEP

 

  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1Device Information
    1. 1.1 Product Description
    2. 1.2 Device Details
  5. 2Total Dose Test Setup
    1. 2.1 Test Overview
    2. 2.2 Test Description and Facilities
    3. 2.3 Test Setup Details
      1. 2.3.1 Biased
    4. 2.4 Test Configuration and Condition
  6. 3Total Ionizing Dose (RHA) Characterization Test Results
    1. 3.1 Total Ionizing Dose RHA Characterization Summary Results
  7. 4Applicable and Reference Documents
    1. 4.1 Reference Documents
    2. 4.2 Total Ionizing Dose HDR and LDR Reports

Test Configuration and Condition

Prior to and after testing, electrical tests were performed on a given sample of parts to verify that the units are within specified data sheet electrical test limits. 5 samples were used at the 10 mrad(si)/s dose level for HDR and 5 samples were used at the 170-260 rad(Si)/s dose level for HDR with biased setup conditions per Table 2-2 and Table 2-3.

Table 2-2 LDR Biased Conditions
LDR = 10 mrad(Si)/s
Total Samples: 5/dose level
Exposure Levels
30 krad(Si), Unit#s 4, 5 ,6 ,7, 8
Passed
Table 2-3 HDR Biased Conditions
HDR = 172-260 rad(Si)/s
Total Samples: 5/dose level
Exposure Levels:
30 krad(Si), Unit#s 50, 51, 52, 53, 54
Passed