Total Ionizing Dose RHA Characterization Summary Results

ADC168M102R-SEP passed HDR and LDR up to 30Krad at the maximum recommended operating conditions. The drifts of critical parameters were within the specification. ELDRS study was also performed and HDR was worst case. 30 kRads HDR are used for radiation lot acceptance.