SBAK035 January 2025 ADC168M102R-SEP
Table 1-1 lists the device information used for TID HDR characterization and qualification.
| TID HDR Details: | |
|---|---|
| TI Device Number | ADC168M102R-SEP |
| Package | 32-RHB |
| Technology | HPA07 |
| Die Lot Number | 3713261 |
| A/T Lot Number / Lot Trace Code |
4493181MLA / 46ARCTI |
| Quantity Tested | 5 units + 1 control units |
| Lot Accept/Reject | 5 / 0 |
| HDR Radiation Facility | Texas Instruments CLAB, Dallas, TX |
| HDR Dose Level | 30 Krad(Si) |
| HDR Dose Rate | 170-260 rad(Si)/s ionizing radiation with increments |
| HDR Radiation Source | Gamma (GR420) Co-60 |
| Irradiation Temperature | Ambient, room temperature |
| Irradiation and Test Temperature |
Ambient, room temperature controlled to 24°C ±6°C per MIL-STD-883 and MIL-STD-750 |
Table 1-2 lists the device information used for TID LDR characterization and qualification.
| TID LDR Details: | |
|---|---|
| TI Device Number | ADC168M102R-SEP |
| Package | 32-RHB |
| Technology | HPA07 |
| Die Lot Number | 3612490 |
| A/T Lot Number / Lot Trace Code |
3958191MLA / 3CC3JXK |
| Quantity Tested | 5 units + 1 control units |
| Lot Accept/Reject | 5 / 0 |
| LDR Radiation Facility | Radiation Test Solutions, Inc. Colorado Springs, CO |
| LDR Dose Level | 30 Krad(Si) |
| LDR Dose Rate | 10mrad(Si)/s ionizing radiation with increments |
| LDR Radiation Source | Gamma rays provided by JLSA 81-20/81-22 Co60 LDR source |
| Irradiation Temperature | Ambient, room temperature |
| Irradiation and Test Temperature |
Ambient, room temperature controlled to 24°C ±6°C per MIL-STD-883 and MIL-STD-750 |