SBASAL0A August 2025 – October 2025 ADC34RF72
PRODUCTION DATA
The ADC34RF72 uses internal background calibration to maintain a high AC performance over temperature. The calibration is performed periodically and does not require any user control or input signal, and so on. During calibration, small changes to the signal offset are observed (approximately 30 LSB). This calibration can be frozen to avoid any disturbance during measurements using SPI writes or GPIO control.
| FIN = 100MHz, AIN = -1dBFS, Calibration at 25°C |