SBASAP4 April 2025 ADC3664-EP , ADC3664-SEP
PRODUCTION DATA
The ADC3664-xEP requires external DC bias using the common mode output voltage (VCM) of the ADC together with the termination network as shown in Figure 7-6. The termination is located within the glitch filter network. When using a balun on the input, the termination impedance has to be adjusted to account for the turns ratio of the transformer. When using an amplifier, the termination impedance is adjusted to optimize the amplifier performance.
Figure 7-6 AC-Coupling: termination network provides DC bias (glitch filter example for up to 60MHz)