SBASBC4A
December 2025 – June 2026
ADS8688W
PRODUCTION DATA
1
1
Features
2
Applications
3
Description
4
Device Comparison Table
5
Pin Configuration and Functions
6
Specifications
6.1
Absolute Maximum Ratings
6.2
ESD Ratings
6.3
Recommended Operating Conditions
6.4
Thermal Information
6.5
Electrical Characteristics
6.6
Timing Requirements
6.7
Switching Characteristics
6.8
Timing Diagrams
6.9
Typical Characteristics
7
Detailed Description
7.1
Overview
7.2
Functional Block Diagram
7.3
Feature Description
7.3.1
Analog Inputs
7.3.2
Analog Input Impedance
7.3.3
Input Overvoltage Protection Circuit
7.3.4
Programmable Gain Amplifier (PGA)
7.3.5
Second-Order, Low-Pass Filter (LPF)
7.3.6
ADC Driver
7.3.7
Multiplexer (MUX)
7.3.8
Reference
7.3.8.1
Internal Reference
7.3.8.2
External Reference
7.3.9
Auxiliary Channel
7.3.9.1
Input Driver for the AUX Channel
7.3.10
ADC Transfer Function
7.3.11
Alarm Feature
7.4
Device Functional Modes
7.4.1
Device Interface
7.4.1.1
Digital Pin Description
7.4.1.1.1
CS (Input)
7.4.1.1.2
SCLK (Input)
7.4.1.1.3
SDI (Input)
7.4.1.1.4
SDO (Output)
7.4.1.1.5
DAISY (Input)
7.4.1.1.6
RST / PD (Input)
7.4.1.2
Data Acquisition Example
7.4.1.3
Host-to-Device Connection Topologies
7.4.1.3.1
Daisy-Chain Topology
7.4.1.3.2
Star Topology
7.4.2
Device Modes
7.4.2.1
Continued Operation in the Selected Mode (NO_OP)
7.4.2.2
Frame Abort Condition (FRAME_ABORT)
7.4.2.3
STANDBY Mode (STDBY)
7.4.2.4
Power-Down Mode (PWR_DN)
7.4.2.5
Auto Channel Enable With Reset (AUTO_RST)
7.4.2.6
Manual Channel n Select (MAN_Ch_n)
7.4.2.7
Channel Sequencing Modes
7.4.2.8
Reset Program Registers (RST)
8
Register Maps
8.1
Command Register Description
8.2
Program Register Description
8.2.1
Program Register Read/Write Operation
8.2.2
Program Register Map
8.2.2.1
Auto-Scan Sequencing Control Registers
8.2.2.1.1
Auto-Scan Sequence Enable Register (address = 01h)
8.2.2.1.2
Channel Power Down Register (address = 02h)
8.2.2.2
Alarm Flag Registers (Read-Only)
8.2.2.2.1
ALARM Overview Tripped-Flag Register (address = 10h)
8.2.2.2.2
Alarm Flag Registers: Tripped and Active (address = 11h to 14h)
8.2.2.2.3
Alarm Threshold Setting Registers
8.2.2.3
Device Features Selection Control Register (address = 03h)
8.2.2.4
Range Select Registers (addresses 05h-0Ch)
8.2.2.5
Command Read-Back Register (address = 3Fh)
9
Application and Implementation
9.1
Application Information
9.2
Typical Applications
9.2.1
Phase-Compensated, 8-Channel, Multiplexed Data Acquisition System for Power Automation
9.2.1.1
Design Requirements
9.2.1.2
Detailed Design Procedure
9.2.1.3
78
9.3
Power Supply Recommendations
9.4
Layout
9.4.1
Layout Guidelines
9.4.2
Layout Example
10
Device and Documentation Support
10.1
Documentation Support
10.1.1
Related Documentation
10.2
Receiving Notification of Documentation Updates
10.3
Support Resources
10.4
Trademarks
10.5
Electrostatic Discharge Caution
10.6
Glossary
11
Revision History
12
Mechanical, Packaging, and Orderable Information
12.1
Mechanical Data
1
Features
16
-Bit ADCs with Integrated Analog Front-End
4-,
8-Channel MUX with Auto and Manual Scan
Channel-Independent Programmable Inputs:
±12.288V, ±6.144V, and ±3.072V
12.288V to 0V and 6.144V to 0V
5V Analog Supply: 1.65V to 5V I/O Supply
Constant Resistive Input Impedance: 1.2MΩ
Input Overvoltage Protection: Up to ±20V
On-Chip, 4.096V Reference with Low Drift
Excellent Performance:
500kSPS Aggregate Throughput
DNL: ±0.6LSB; INL: ±0.8LSB
Low Drift for Gain Error and Offset
SNR: 91.5dB; THD: –102dB
Low Power: 65mW
AUX Input → Direct Connection to ADC Inputs
ALARM → High and Low Thresholds per Channel
SPI™
-Compatible Interface with Daisy-Chain
Industrial Temperature Range: –40°C to 125°C
Block Diagram