SBOS576C May 2012 – September 2025 INA3221
PRODUCTION DATA
| POINTER ADDRESS (Hex) | REGISTER NAME | DESCRIPTION | POWER-ON RESET | TYPE(1) | |
|---|---|---|---|---|---|
| BINARY | HEX | ||||
| 0 | Configuration | All-register reset, shunt and bus voltage ADC conversion times and averaging, operating mode. | 01110001 00100111 | 7127 | R/ W |
| 1 | Channel-1 Shunt Voltage | Averaged shunt voltage value. | 00000000 00000000 | 0000 | R |
| 2 | Channel-1 Bus Voltage | Averaged bus voltage value. | 00000000 00000000 | 0000 | R |
| 3 | Channel-2 Shunt Voltage | Averaged shunt voltage value. | 00000000 00000000 | 0000 | R |
| 4 | Channel-2 Bus Voltage | Averaged bus voltage value. | 00000000 00000000 | 0000 | R |
| 5 | Channel-3 Shunt Voltage | Averaged shunt voltage value. | 00000000 00000000 | 0000 | R |
| 6 | Channel-3 Bus Voltage | Averaged bus voltage value. | 00000000 00000000 | 0000 | R |
| 7 | Channel-1 Critical Alert Limit | Contains limit value to compare each conversion value to determine if the corresponding limit has been exceeded. | 01111111 11111000 | 7FF8 | R/ W |
| 8 | Channel-1 Warning Alert Limit | Contains limit value to compare to averaged measurement to determine if the corresponding limit has been exceeded. | 01111111 11111000 | 7FF8 | R/ W |
| 9 | Channel-2 Critical Alert Limit | Contains limit value to compare each conversion value to determine if the corresponding limit has been exceeded. | 01111111 11111000 | 7FF8 | R/ W |
| A | Channel-2 Warning Alert Limit | Contains limit value to compare to averaged measurement to determine if the corresponding limit has been exceeded. | 01111111 11111000 | 7FF8 | R/ W |
| B | Channel-3 Critical Alert Limit | Contains limit value to compare each conversion value to determine if the corresponding limit has been exceeded. | 01111111 11111000 | 7FF8 | R/ W |
| C | Channel-3 Warning Alert Limit | Contains limit value to compare to averaged measurement to determine if the corresponding limit has been exceeded. | 01111111 11111000 | 7FF8 | R/ W |
| D | Shunt-Voltage Sum | Contains the summed value of the each of the selected shunt voltage conversions. | 00000000 00000000 | 0000 | R |
| E | Shunt-Voltage Sum Limit | Contains limit value to compare to the Shunt Voltage Sum register to determine if the corresponding limit has been exceeded. | 01111111 11111110 | 7FFE | R/ W |
| F | Mask/Enable | Alert configuration, alert status indication, summation control and status. | 00000000 00000010 | 0002 | R/ W |
| 10 | Power-Valid Upper Limit | Contains limit value to compare all bus voltage conversions to determine if the Power Valid level has been reached. | 00100111 00010000 | 2710 | R/ W |
| 11 | Power-Valid Lower Limit | Contains limit value to compare all bus voltage conversions to determine if the any voltage rail has dropped below the Power Valid range. | 00100011 00101000 | 2328 | R/ W |
| FE | Manufacturer ID | Contains unique manufacturer identification number. | 01010100 01001001 | 5449 | R |
| FF | Die ID | Contains unique die identification number. | 00110010 00100000 | 3220 | R |