SBOS576C May   2012  – September 2026 INA3221

PRODUCTION DATA  

  1.   1
  2. 1 Features
  3. 2 Applications
  4. 3 Description
  5. 4 Device Comparison Table
  6. 5 Pin Configuration and Functions
  7. 6 Specifications
    1. 6.1 Absolute Maximum Ratings
    2. 6.2 ESD Ratings
    3. 6.3 Recommended Operating Conditions
    4. 6.4 Thermal Information
    5. 6.5 Electrical Characteristics
    6. 6.6 Typical Characteristics
  8. 7 Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Basic ADC Functions
      2. 7.3.2 Alert Monitoring
        1. 7.3.2.1 Critical Alert
          1. 7.3.2.1.1 Summation Control Function
        2. 7.3.2.2 Warning Alert
        3. 7.3.2.3 Power-Valid Alert
        4. 7.3.2.4 Timing-Control Alert
        5. 7.3.2.5 Default Settings
      3. 7.3.3 Software Reset
    4. 7.4 Device Functional Modes
      1. 7.4.1 Averaging Function
      2. 7.4.2 Multiple Channel Monitoring
        1. 7.4.2.1 Channel Configuration
        2. 7.4.2.2 Averaging and Conversion-Time Considerations
      3. 7.4.3 Filtering and Input Considerations
    5. 7.5 Programming
      1. 7.5.1 Bus Overview
        1. 7.5.1.1 Serial Bus Address
        2. 7.5.1.2 Serial Interface
      2. 7.5.2 Writing To and Reading From the INA3221
        1. 7.5.2.1 High-Speed I2C Mode
      3. 7.5.3 SMBus Alert Response
  9. 8 Register Maps
    1. 8.1 Summary of Register Set
    2. 8.2 Register Descriptions
      1. 8.2.1  Configuration Register (address = 00h) [reset = 7127h]
      2. 8.2.2  Channel-1 Shunt-Voltage Register (address = 01h), [reset = 00h]
      3. 8.2.3  Channel-1 Bus-Voltage Register (address = 02h) [reset = 00h]
      4. 8.2.4  Channel-2 Shunt-Voltage Register (address = 03h) [reset = 00h]
      5. 8.2.5  Channel-2 Bus-Voltage Register (address = 04h) [reset = 00h]
      6. 8.2.6  Channel-3 Shunt-Voltage Register (address = 05h) [reset = 00h]
      7. 8.2.7  Channel-3 Bus-Voltage Register (address = 06h) [reset = 00h]
      8. 8.2.8  Channel-1 Critical-Alert Limit Register (address = 07h) [reset = 7FF8h]
      9. 8.2.9  Warning-Alert Channel-1 Limit Register (address = 08h) [reset = 7FF8h]
      10. 8.2.10 Channel-2 Critical-Alert Limit Register (address = 09h) [reset = 7FF8h]
      11. 8.2.11 Channel-2 Warning-Alert Limit Register (address = 0Ah) [reset = 7FF8h]
      12. 8.2.12 Channel-3 Critical-Alert Limit Register (address = 0Bh) [reset = 7FF8h]
      13. 8.2.13 Channel-3 Warning-Alert Limit Register (address = 0Ch) [reset = 7FF8h]
      14. 8.2.14 Shunt-Voltage Sum Register (address = 0Dh) [reset = 00h]
      15. 8.2.15 Shunt-Voltage Sum-Limit Register (address = 0Eh) [reset = 7FFEh]
      16. 8.2.16 Mask/Enable Register (address = 0Fh) [reset = 0002h]
      17. 8.2.17 Power-valid Upper-limit Register (address = 10h) [reset = 2710h]
      18. 8.2.18 Power-Valid Lower-Limit Register (address = 11h) [reset = 2328h]
      19. 8.2.19 Manufacturer ID Register (address = FEh) [reset = 5449h]
      20. 8.2.20 Die ID Register (address = FFh) [reset = 3220]
  10. 9 Application and Implementation
    1. 9.1 Application Information
    2. 9.2 Typical Application
      1. 9.2.1 Design Requirements
      2. 9.2.2 Detailed Design Procedure
      3. 9.2.3 Application Curves
    3. 9.3 Power Supply Recommendations
    4. 9.4 Layout
      1. 9.4.1 Layout Guidelines
      2. 9.4.2 Layout Example
  11. 10Device and Documentation Support
    1. 10.1 Device Support
      1. 10.1.1 Development Support
    2. 10.2 Documentation Support
      1. 10.2.1 Related Documentation
    3. 10.3 Receiving Notification of Documentation Updates
    4. 10.4 Support Resources
    5. 10.5 Trademarks
    6. 10.6 Electrostatic Discharge Caution
    7. 10.7 Glossary
  12. 11Revision History
  13. 12Mechanical, Packaging, and Orderable Information

Filtering and Input Considerations

Measuring current is often noisy, and such noise can be difficult to define. The INA3221 offers several filtering options by allowing conversion times and the number of averages to be selected independently in the Configuration register. The conversion times can be set independently for the shunt- and bus-voltage measurements as well, for added flexibility in configuring power-supply bus monitoring.

The internal ADC is based on a delta-sigma (ΔΣ) front-end with a 500kHz (±30%) typical sampling rate. This architecture has good inherent noise rejection; however, transients that occur at or very close to the sampling-rate harmonics can cause problems. These transient signals are at 1MHz and higher; therefore, the signals are managed by incorporating filtering at the INA3221 input. High-frequency signals allow for the use of low-value series resistors on the filter, with negligible effects on measurement accuracy. In general, filtering the INA3221 input is only necessary if there are transients at exact harmonics of the 500kHz (±30%) sampling rate that are greater than 1MHz. Filter using the lowest-possible series resistance (typically 10Ω or less) and a ceramic capacitor. Recommended capacitor values are 0.1μF to 1.0μF. Figure 7-8 shows the INA3221 with an additional filter added at the input.

INA3221 INA3221 With Input FilteringFigure 7-8 INA3221 With Input Filtering

The INA3221 inputs are specified to tolerate 26V across the inputs. However, overload conditions are another consideration for the INA3221 inputs. For example, a large differential-input scenario can be a short to ground on the load side of the shunt. This type of event results in the full power-supply voltage applied across the shunt, if supported by the power supply or energy-storage capacitors. Keep in mind that removing a short to ground can result in inductive kickbacks that can exceed the 26V differential and common-mode rating of the INA3221. Inductive kickback voltages are best controlled by zener-type transient-absorbing devices (commonly called transzorbs) combined with sufficient energy-storage capacitance.

In applications that do not have large energy-storage electrolytic capacitors on one or both sides of the shunt, an input overstress condition can result from an excessive dV/dt of the voltage applied to the input. A hard physical short is the most likely cause of this event, particularly in applications without large electrolytic capacitors present. This problem occurs because an excessive dV/dt can activate the INA3221 ESD protection in systems where large currents are available. Testing has demonstrated that the addition of 10Ω resistors in series with each INA3221 input sufficiently protects the inputs against this dV/dt failure up to the 26V device rating.