Connect your target speaker to the L+ and L- pins of the learning board, and make sure your speaker has been held stabilized (possibly with some adhesive putty). Then click the Start IV Measurement button to start the IV measurement process. Be aware that a certain level of noise can be heard during the measurement process.
Figure 4-8 Example of Model Fitting
ResultsWait until the Model Fit process is completed, and observe the fitting results on the Review Speaker Model page, and the light blue curve (measured impedance) needs to align well with the dark blue curve (fitted impedance), like shown in Figure 4-8. If so, you can click the Accept button to move to the next step. If not, you need to check your hardware and software configuration and click the Re-run IV Measurement button to re-run the IV measurement process.