SLASFB7A November 2024 – August 2025 TAS5802
PRODUCTION DATA
Once the PVDD voltage exceeds the OVETHRES(PVDD), device will set the output driver from Play mode to Hi-Z mode. Over voltage fault reported by GLOBAL_FAULT1 Register (Offset = 71h) [Reset = 00h] in Book0/Page0. Once PVDD voltage returns to normal, device will come back to Play mode. But this bit still keeps 1 unless clear it by FAULT_CLEAR Register (Offset = 78h) [Reset = 00h] in Book0/Page0 manually.