SLDS204D October 2014 – February 2025 PGA300
PRODUCTION DATA
The write operation on the one-wire interface consists of a single OWI frame. The command field of the write operation specifies which control and status register page to write to. The first data field specifies which address within that control and status register page to write to. The second data field contains the data to write to the specified register in the target (that is, the PGA300). Figure 6-18 shows the write operation. Sending data fields three to eight is optional. The target ignores those additional data fields.