SLDS204D October 2014 – February 2025 PGA300
PRODUCTION DATA
| PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT | |
|---|---|---|---|---|---|---|
| Absolute-voltage output mode, overall accuracy (PGA300 only, no sense element)(1) | 3 pressure - 1 temperature calibration, overall accuracy calculated using points different from points used for calibration | 0.2 | %FSO | |||
| 3 pressure - 3 temperature calibration, input voltage not subject to temperature variation, overall accuracy calculated using points different from points used for calibration | 0.1 | %FSO | ||||
| 4 pressure - 4 temperature calibration, input voltage not subject to temperature variation, overall accuracy calculated using points different from points used for calibration | 0.08 | %FSO | ||||
| Ratiometric-voltage output mode, overall accuracy (PGA300, no sense element)(1) | 3 pressure - 1 temperature calibration, overall accuracy calculated using points different from points used for calibration | 0.5 | %FSO | |||
| 3 pressure - 3 temperature calibration, input voltage not subject to temperature variation, overall accuracy calculated using points different from points used for calibration | 0.25 | %FSO | ||||
| 4 pressure - 4 temperature calibration, input voltage not subject to temperature variation, overall accuracy calculated using points different from points used for calibration | 0.2 | %FSO | ||||
| Current output mode, overall accuracy (PGA300, no sense element)(1) | 3 pressure - 1 temperature calibration, overall accuracy calculated using points different from points used for calibration | 0.2 | %FSO | |||
| 3 pressure - 3 temperature calibration, input voltage not subject to temperature variation, overall accuracy calculated using points different from points used for calibration | 0.1 | %FSO | ||||
| 4 pressure - 4 temperature calibration, input voltage not subject to temperature variation, overall accuracy calculated using points different from points used for calibration | 0.09 | %FSO | ||||