11 Revision History
Changes from Revision H (June 2024) to Revision I (August 2026)
- Updated VDE and IEC standard names and revisions throughout the
documentGo
- Changed VIOWM DC Voltage from 1500 to 2121Go
- Updated the test conditions for VIOSM and
qpd
Go
- Changed the maximum surge isolation voltage for ISO141x devices from 6250 to
10000Go
- Changed the maximum surge isolation voltage for ISO141xB devices from 4615
to 6000Go
- Updated the document to change legacy terminology to "Controller" and
"Target"Go
- Updated the Insulation Lifetime section to update lifetime values and
update the Insulation Lifetime Projection Data graphGo
Changes from Revision G (May 2020) to Revision H (June 2024)
- Updated the number format for tables, figures, and cross-references
throughout the documentGo
Changes from Revision E (October 2019) to Revision F (February 2020)
- Updated the Safety-Related Certifications section to the latest
certification qualificationsGo
- Added updated certification information in Safety-Related Certifications
Go
Changes from Revision D (May 2019) to Revision E (October 2019)
- Added footnote to Pin functions table for NC pins Go
Changes from Revision C (April 2019) to Revision D (May 2019)
- Added B part numbers throughout datasheet Go
Changes from Revision B (November 2018) to Revision C (April 2019)
- Added ISO1430, ISO1432, ISO1450, ISO1452 in Device Information
tableGo
- Changed Device Features tables to Device Comparison
tableGo
- Changed the position of Device Features tables Go
- Added footnote to Pin Functions: Full-Duplex DeviceGo
- Added footnote to Pin Functions: Half-Duplex DeviceGo
- Added Typical curves for ISO143x and ISO145x in
Section 6.16
Go
- Added Section 11.2.3 Application Curves and Section 11.2.3.1 Insulation LifetimeGo
Changes from Revision A (August 2018) to Revision B (November 2018)
- Changed status to production data Go
Changes from Revision * (July 2018) to Revision A (August 2018)
- Changed the designator of common mode voltage in Recommended
operating condition to VI
Go
- Added test condition for CMTI in Electrical characteristics: Driver Go
- Added test condition for CMTI in Electrical characteristics:
ReceiverGo
- Changed VTEST to VCM in the Common Mode Transient Immunity
(CMTI)—Full Duplex and Common Mode Transient Immunity (CMTI)—Half
Duplex figures in the Parameter Measurement Information
sectionGo
- Changed tPLH to tPZH and tPLZ to tPHZ in the first Driver Enable and Disable Times timing diagram in the Parameter Measurement Information sectionGo
- Added tPHZ to the first Receiver Enable and Disable Times timing diagram in the Parameter Measurement Information section Go