SLLSFB7 March 2026 TLIN1124A-Q1
ADVANCE INFORMATION
The device is protected by limiting the on-chip power dissipation in fault scenarios. If the junction temperature, TJ , of the device exceeds the thermal shutdown threshold rising threshold TSDR, the device will react depending on the current state (see below). Once the over temperature fault condition has been removed and the junction temperature has cooled beyond the hysteresis temperature, device transitions to the previous state before thermal shutdown (TSD) had occurred.
Normal Mode
During a TSD event, the control logic puts all the LINx transmitters into the recessive state and the commander termination RCOMMANDER is switched off for all channels. INHN is kept at the same logic as before entering TSD, while TXDx, SLP pins are ignored.
Standby Mode
During a TSD event, the control logic puts all the LINx transmitters into the recessive state and the commander termination RCOMMANDER is switched off for all channels. INHN is kept same at the logic as before entering TSD, while TXDx, SLP pins are ignored. Received wakeup events are cleared while in over temperature state (RXDx is made high).
Sleep Mode
In sleep mode, the over temperature monitor is turned off for power savings.