SLLSFB7 March   2026 TLIN1124A-Q1

ADVANCE INFORMATION  

  1.   1
  2. 1 Features
  3. 2 Applications
  4. 3 Description
  5. 4 Pin Configuration and Functions
  6. 5 Specifications
    1. 5.1 Absolute Maximum Ratings
    2. 5.2 ESD Ratings
    3. 5.3 ESD Ratings - IEC Specification
    4. 5.4 Recommended Operating Conditions
    5. 5.5 Thermal Information
    6. 5.6 Power Supply Characteristics
    7. 5.7 Electrical Characteristics
    8. 5.8 AC Switching Characteristics
    9. 5.9 Typical Characteristics
  7. 6 Parameter Measurement Information
  8. 7 Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 LIN (Local Interconnect Network) Bus
        1. 7.3.1.1 LIN Transmitter Characteristics
        2. 7.3.1.2 LIN Receiver Characteristics
          1. 7.3.1.2.1 Termination
      2. 7.3.2 TXDx (Transmit Input and Output)
      3. 7.3.3 RXDx (Receive Output)
      4. 7.3.4 VSUP (Supply Voltage)
      5. 7.3.5 VIO (logic interface supply voltage)
      6. 7.3.6 GND (Ground)
      7. 7.3.7 SLP (Sleep Input)
      8. 7.3.8 INHN (Inhibit high voltage output terminal)
      9. 7.3.9 Protection Features
        1. 7.3.9.1 TXD Dominant Time Out (TXD DTO)
        2. 7.3.9.2 LIN Dominant timeout (LIN DTO)
        3. 7.3.9.3 Thermal Shutdown
        4. 7.3.9.4 Under Voltage on VSUP and VIO
        5. 7.3.9.5 Unpowered Device and LIN Bus
    4. 7.4 Device Functional Modes
      1. 7.4.1 Normal Mode
      2. 7.4.2 Sleep Mode
      3. 7.4.3 Standby Mode
      4. 7.4.4 Wake Up Events
        1. 7.4.4.1 Wake Up Request (RXD)
        2. 7.4.4.2 Mode Transitions
  9. 8 Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
        1. 8.2.1.1 Detailed Design Procedure
    3. 8.3 Power Supply Recommendations
    4. 8.4 Layout
      1. 8.4.1 Layout Guidelines
      2. 8.4.2 Layout Example
  10. 9 Device and Documentation Support
    1. 9.1 Documentation Support
    2. 9.2 Receiving Notification of Documentation Updates
    3. 9.3 Support Resources
    4. 9.4 Trademarks
    5. 9.5 Electrostatic Discharge Caution
    6. 9.6 Glossary
  11. 10Revision History
  12. 11Mechanical, Packaging, and Orderable Information
    1. 11.1 Package Option Addendum
    2. 11.2 Tape and Reel Information
    3. 11.3 Mechanical Data

Wake Up Events

The TLIN1124A-Q1 supports two methods for wake-up from sleep mode:

  • Wake-up over the LIN bus via the LIN wake-up receiver: Remote wake-up initiated by the falling edge of a recessive-to-dominant state transition on the LIN bus where the dominant state is be held than tLINBUS filter time. After the tLINBUS filter time has been met, a rising edge on the LIN bus going from dominant-to-recessive initiates a remote wake-up event. The pattern and tLINBUS filter time used for the LIN wake-up prevents noise and bus stuck dominant faults from causing false wake requests.
  • For a local wake-up via the SLP pin, the SLP pin must be set low for t > tMODE_CHANGE for the device to wake-up and fully transition to normal mode within tNOMINT.