over operating free-air temperature range (unless otherwise noted)(1)
|
MIN |
MAX |
UNIT |
| VS |
Supply voltage (total bipolar supplies)(2) |
|
±14 |
V |
| VIN |
Input voltage |
VS– – 0.5 |
VS+ + 0.5 |
V |
| VIN,Diff |
Differential input voltage(3) |
|
±7 |
V |
| II |
Continuous input current |
|
±10 |
mA |
| IO |
Continuous output current(4) |
|
±15 |
mA |
| PD |
Continuous power dissipation |
See Section 6.4 |
|
| TJ |
Junction temperature |
|
150 |
°C |
| Tstg |
Storage temperature |
–65 |
125 |
°C |
(1) Operation outside the Absolute Maximum Ratings can cause permanent device damage. Absolute Maximum Ratings do not imply functional operation of the device at these or any other conditions beyond those listed under Recommended Operating Conditions. If used outside the Recommended Operating Conditions but within the Absolute Maximum Ratings, the device can not be fully functional, and this can affect device reliability, functionality, performance, and shorten the device lifetime.
(2) VS is the total supply voltage given by VS = VS+ – VS– .
(3) Equal to the lower of ±7V or total supply voltage.
(4) Long-term continuous output current for electromigration limits.